G_EN_08
48
14.2.2 Registering the RF remote control again in case of lack of communication between the remote
control and the receiver:
14.2.3 Receiving sensitivity of the RF remote control and the receiver.
14.2.4 Possible error indications.
Fault
code
Fault type
Description
F00
No fault / power-up
This indicates no fault situation. The value is set to zero in case
of a power-up of the DFGT
F01
ESYS communication failure
The communication with the ESYS electronic burner unit fails
Check wiring
F02
Internal temparture to high
The internal temperature of the DFGT is too high
Check if the ventilation of the electronics is sufficient
F03
Internal NTC fault
F04
External NTC fault
The external NTC sernsor is not operating correctly
Check NTC sensor and wiring
F05
Internal safety fault / incorrect
configuration of Ignition Control
Type
Internal safety fault or the DFGT is not configured correctly
Reconfiguration of DFGT is needed by manufacturer
F06
RF communicaton timeout
No communication anymore between remote control and DFGT
Check power supply, red LED on DFGT is blincking at slow
beat if current is present
Distance between remote control and DFGT is too long.
Decrease distance. If error persists, reinitialize remote control
following procedure on page 14.2.2
F07
No flame and fault feedback from
esys (timeout on flame)
Error message can only occur when switching on the fireplace,
that is when igniting the pilot flame.
Check whether on ignition a spark is produced between the
ignition electrodes of the pilot flame.
Check whether no decorative material has ended up between
the ignition electrodes and the pilot flame. If no spark is
produced, the distance between the ignition electrodes must be
Pull power supply out of wall socket
Press the menu key for 10 seconds until the time indication blinks in the left
upper corner. Then press the menu key shortly again. The screen indication
as shown in the left figure appears.
Repower power supply
Press both scroll arrows simultaneously.
The registration is started and the screen indication as shown on the left
figure appears. As long as the hourglass symbol is shown, the registration
procedure is in progress.
Press the on-off key together with the left scroll arrow. The screen as shown
on the left figure appears.
The intensity of the acknowledgement signal is shown.
In the left upper corner the signal intensity of the remote control can be read,
below on the right that of the receiver.
A value between -20 and -70 is good.
A value between -80 and -100 is bad.
If necessary, keep the remote control closer to the fireplace.