4 Intended use

Transmission of audio signals via fiber over long distances without signal losses

Use of the optimized components from mk messtechnik GmbH only (correct optical fiber, charger, batteries)

Charging of the batteries with provided chargers from mk messtechnik GmbH only

Non-OEM parts, e.g. power supply modules influence the EMC performance and may cause damages to the 
system

5 Disclaimer of Warranty/Exclusion of Liability

§

Under the Following Circumstances the Warranty and Liability is Excluded:

Usage not according to the intended purpose and misapplication

Non-observance of the safety instructions

Manipulation and modification of the devices

6 Special Regulations and Notes

The following regulations have to be respected for all devices. Additionally, all the specific notes for each device 
have to be respected (see the following chapters).

6.1 Safety

Interferences that are not described in chapter 11, and any damage of the devices (e.g. damaged housing or 
damaged cables at the charger) have to be reported to the responsible expert immediately.
The affected device has to be decommissioned by the responsible expert and must be protected against incorrect 
usage until all damages have been repaired.

6.2 Product Care and Maintenance

Battery packs of the devices have to be maintained on a regular basis (see chapter 9).

Charging of the battery packs has to be done according to the instructions described in chapter 9.3.

Other components of the devices are maintenance free.

Repairs must only be done by the manufacturer.

§

Risk of fire, injury, and damage to the electronics

There are no user serviceable parts in the devices. Opening the devices can lead to short 
circuits if powered components touch the housing of the device. Therefore NEVER open the 

housings, because there is a risk of fire or injury!
In case of errors consider the notes in chapter 11. If an an error cannot be solved by 
considering these notes, please send the device in for repair. In this case please contact mk 

messtechnik GmbH BEFORE you send in the device.

Page 6 / 23

Distributed by: Reliant EMC LLC, 3311 Lewis Ave, Signal Hill CA 90755, 408­916­5750, www.reliantemc.com

 

Summary of Contents for dAV-TRX

Page 1: ...Intercom dAV TRX Manual Intercom system with digital optical transmission Distributed by Reliant EMC LLC 3311 Lewis Ave Signal Hill CA 90755 408 916 5750 www reliantemc com...

Page 2: ...technik Gmb Contact Distrubuted by Reliant EMC 3311 Lewis Ave Signal Hill CA 90755 Tel 1 408 916 5750 contact reliantemc com www reliantemc com WEEE Reg No DE 21806070 Operating Instructions revision...

Page 3: ...7 7 Back Side of the Console Device 11 7 8 Front Side of the Secondary Mic 12 7 9 Back Side of the Secondary Mic 13 7 10 Initial Operation 14 8 Operation 15 8 1 Start Stop talking 15 8 2 Volume Contr...

Page 4: ...sceiver 21 12 1 1 1 Mobile Device 21 12 1 1 2 Console Device 21 12 1 2 Secondary Mic 21 12 2 Charger 22 12 3 Battery Pack 22 13 Accessories Spare parts 23 Page 4 23 Distributed by Reliant EMC LLC 3311...

Page 5: ...ation The Intercom system is used for optical transmission of audio signals speech 3 Properties The system is suited for the undisturbed isolated transmission of audio signals in surroundings with hig...

Page 6: ...damaged housing or damaged cables at the charger have to be reported to the responsible expert immediately The affected device has to be decommissioned by the responsible expert and must be protected...

Page 7: ...the devices only on skid proof surfaces respect the specific installation references for each device Electrical connections are only allowed to be done by authorized EMC trained specialist staff Cons...

Page 8: ...apture audio signals Integrated microphone Mic On Off On Switch to On to activate permanent talking switch to Off to deactivate permanent talking push to On and hold to talk temporary release from On...

Page 9: ...Charge DC In Optical In Sig Detect Optical Out PC Figure 7 1 back side of mobile device Sig Detect Permanently on when light is received via the optical link permanently off when no light is received...

Page 10: ...me In Info Power Volume In PTT Mic 1 Mic 2 Figure 7 3 front side of console device with 2 channels Page 10 23 Figure 7 2 front side of console device dAV TRX Info Volume Out PTT Power Volume In Line I...

Page 11: ...ng temporary Push button Line In Mic optional Switch to Line In to activate transmission of line in signal switch to Mic to activate transmission of mic signal Switch button Volume In Turn right to in...

Page 12: ...Switch button Line Out optional Output for line signal received via optical link Socket Cinch Line In optional Input for line signal transmitted via optical link Socket Cinch Audio Out optional Outpu...

Page 13: ...pture audio signals 3 pole socket XLR connector PTT Push to talk Push and release 250ms to activate deactivate permanent talking push and hold 250ms to talk temporary release to stop talking temporary...

Page 14: ...the speaker volume If necessary turn the Volume In knob on console device to adjust the mic gain Switch the Mic button to On on mobile device to start talking Power LED blinks Turn the Volume Out kno...

Page 15: ...button in this position The button switches automatically back to Off when you release it Only one station can talk at a time A blinking power LED indicates that talking is active Example The Mic butt...

Page 16: ...le device at a time A blinking power PTT LED indicates that talking is active Example The console device is set to permanent talking If the PTT button of the secondary mic is pushed the mic of the con...

Page 17: ...tions and References Protect the batteries from heat e g long exposure to direct sunlight and fire Do not immerse the batteries into fluids Otherwise there is a risk of explosions Risk of Damage and E...

Page 18: ...teries Battery Pack or Integrated into the Device Start of the Charging Process Place the battery pack or the device to charge onto a stable and skidproof surface Turn off the device see appropriate c...

Page 19: ...k GmbH at no cost 10 2 Disposal of Batteries Due to their natural capacity loss batteries must be replaced after their lifespan NEVER open devices or housings by yourself Replacement of batteries must...

Page 20: ...125 m Batteries empty Charge batteries Other device turned off Turn on other device No transmission white noise or silence at the output Device does not receive an optical signal Check fiber optic ca...

Page 21: ...rs upon request Mounting plate with 1 4 thread W x H x D Approx 35 mm x 5 mm x 37 mm Microphone Internal mono single ended 12 1 1 2 Console Device Power supply Shielded power supply 110 V to 230 V for...

Page 22: ...m with 5 pole screw connector Binder 712 series suitable for systems from mk messtechnik GmbH Temperature of operation 0 40 C at maximum load Temperature of storage 40 70 C Protection class IP 40 Ins...

Page 23: ...e parts For an overview of available accessories please visit www mk messtechnik com For spare parts orders and repairs please contact mk messtechnik GmbH Page 23 23 Distributed by Reliant EMC LLC 331...

Reviews: