35.00.EX…
This line identifies the firmware application name, build (release)
date, application identification number and version identification
number.
Hours On
How many hours the MC³ has been powered up, accumulated.
Hours Ran
How many hours the feeding device has been running, accumulated.
Reset to zero by pushing
Clear Hours Ran
button
.
Bd-…
There is no meaningful information in this line.
Modbus Diagnostics
There are two diagnostics screen available for troubleshooting Modbus communications.
Modbus Troubleshooting and monitoring
One screen displays communication related statistics, and one displays data in the
Common Interface Table. For details, see
[MCT]
.
DIAGNOSTIC SETTINGS
This selection takes you to the Diagnostic Settings menu. The menu is password
protected, with default password 1030. Any modifications to parameters in the Diagnostic
Settings are potentially dangerous. It is quite possible to crash the application from here.
Diagnostic Settings
HPAD Settings
You can change the default HPAD scaling here, to improve live load resolution or to
make a somewhat overloaded 3 mV/V load cell operational. Use in conjunction with the
HPAD Diagnostics screen, page 56.
CAL
This value is used by the HPAD Converter to simulate load on the load cell during an
Electronic Calibration, and is normally zero. A non-zero setting will inject a positive load
cell signal before the A/D converter. The injected signal is 0.2 mV/V times the setting. In
the rare occasion of negative dead load, non-zero value can be entered.
ZERO
This value is used by the HPAD Converter to electronically remove dead load from the
load cell signal. This allows the HPAD to operate at a higher Gain and achieve better
resolution when measuring the load cell signal. A non-zero setting will inject a negative
35.00.EX O&M Manual
63
Summary of Contents for MC3 35.00.EX