Logical Input
Description
Drive not Ready
This drive feedback input is used to indicate that the feeding
device drive is not ready to run. The state of the input is
combined with other states to form the
Ready
Logical Output. It
has no other effect, unless you make it qualify a Warning or
Fault.
Drive Overload
This drive feedback input is used to indicate that the feeding
device drive is overloaded. With most drives, the feeding
device will keep running, at least for a while. It has no other
effect, although you should configure it to qualify a Warning.
Available I/0 1-8
These logical I/O points are not used by any function in the
controller. Since they are both Logical Inputs and Logical
Outputs, you can use them for control purposes. If you map a
Physical Input to one of them, and then map a Physical Output
to the same point, the Output will follow the Input, giving you
one or more extra contacts, some of which can be inverted.
Physical Inputs
Physical Inputs
Description
Always Off
The input is always Off.
Always On
The input is always On.
Stable Weight
On when the weight is stable. See Stability Settings on
page 27.
Keyboard Locked
On when the touch screen is locked out by means of
serial communications.
Acc Switch 1 through 4
Access Switches. Not used in this application.
Keyboard A1 – H4
Touch Screen Location Codes. You can map a logical
input to positions on the touch screen. This is useful
for testing purposes.
Rack 1 Input 1
through
4
I/O Rack 1, PCIO 1.
Rack 2 Input 1
through
4
I/O Rack 2, PCIO 1.
Rack 3
Input 1 through
4
I/O Rack 3, PCIO 2.
Rack 4
Input 1 through
4
I/O Rack 4, PCIO 2.
Extern Inputs 1 – 16
The external inputs are set by network
communications. This is useful when you want bits in
a PLC to control I/O in your Feeder Controller. If
outputs
Comm Lost
or
DF1 Timeout
are On all
external inputs are turned Off.
Extern Outputs 1 - 16
It is possible to map a Logical Input to an External
Output. This is useful if you want to wrap a Logical
Output back into the controller as a Logical Input.
Digital Outputs Setup
This screen allows you to change the mapping and properties for the digital outputs. A
Physical Output is always mapped to a Logical.
NOTE
On Always
and
Off Always
are valid logical inputs. You typically map unused physical
outputs to
Off Always
.
Unused
is the same as
Off Always
.
35.00.EX O&M Manual
38
Summary of Contents for MC3 35.00.EX
Page 5: ......