35.00.EX O&M Manual
8
Feeder State Transitions
During operation, the controller state will follow a sequence. This table lists all possible transitions between states. During normal batching, Next
State follows the Current State. All other columns indicate to what state the MC³ will go on an external command. To find out what the controller
will do if you issue a command, start on the row for the current state, and go the column of the command.
Current State
Next State
Start Batch
Stop Batch
Start Fill
Stop Fill
Start Cleanout
Stop
Cleanou
t
Clear Batch
Paused
Note 1
Stable Chk
Before
Re-fill
Cleanout weight
Idle. Note 2
Idle
Note 1
Stable Chk
Before
Re-fill
Cleanout weight
Idle. Note 2
Stable Chk
Before
Fast Feed
Idle. Note 2
Fast Feed Note
3
Fine Feed or
Re-fill. Note 3
Stable Chk
After, Paused
Stable Chk
After, Re-fill
Stable Chk,
Cleanout
Idle. Note 2
Fine Feed Note
4
Stable Chk
After
Stable Chk
After, Paused
Stable Chk
After, Re-fill
Stable Chk,
Cleanout
Idle. Note 2
Stable Chk After
Idle
Cleanout weight
Idle. Note 2
Re-fill
Close Gate
Paused
Stable Chk
Before or Idle
Cleanout weight
Idle. Note 2
Close Gate
Fast Feed or
Idle
Idle.
Note 2
Cleanout weight
Cleanout time
Idle
Idle. Note 2
Cleanout time
Cleanout
Done
Idle
Idle.
Note 2
Cleanout Done
Idle
Re-fill
Idle. Note 2
Summary of Contents for MC3 35.00.EX