The quality of the carbonation process also depends on the temperature of
the water, which means you should wait for the water cooler to have cooled
WKH ZDWHU GRZQ VXI¿FLHQWO\ XSRQ LQVWDOODWLRQ DQG WKH LFH EDQN KDV EHHQ
formed. Both still and carbonated water can be dispensed by pressing the
relative buttons after approximately 40 minutes.
NOTICE
CAUTION! AFTER TRANSPORTING, STORING AND USING CO
2
CYL-
INDERS, FOLLOW LOCAL REGULATIONS CONCERNING THEIR USE.
GB
6.3
CARBONATION DEVICE DRAINAGE
When installing the appliance, or if the water cooler has no water left inside
it, a few air bubbles may enter the carbonation device.
These air bubbles could diminish the quality of the carbonation process,
and we therefore recommend you remove them:
Unscrew the cylinder from the reducer
Remove the casing
Drain the circuit by pulling the outlet valve ring
V
¿J
Re-connect CO
2
cylinder to the reducer
Drain off at least two litres of sparkling water
Replace the casing.
15
Summary of Contents for COSMETAL H2OMY IN F
Page 9: ...HANDBOOK SECTION II 5HVHUYHG WR TXDOL HG RSHUDWRUV 9 ...
Page 21: ...21 ...