(GB)Undercounter
models
NO
WATER
NO
WATER
IN CO
2
IN CO
2
19
17
18
V
Q
R
6
SETTING UP THE SPARKLING WATER (WG and HWG models)
INSTALLATION OF RECHARGEABLE CYLINDERS ( B-RIC)
,WLVDOVRSRVVLEOHWRLQVWDOOUH¿OODEOHF\OLQGHUV%5,&
Remove the ø6mm tube from the installation kit and connect it to the
pressure reducer
R
of the rechargeable (B-RIC) cylinder to the IN CO
2
LQOHWRQWKHWRSSDQHO¿J
Screw the pressure reducer cap to the cylinder attachment paying atten-
tion to the gasket.
Open the cylinder valve
V
.
The screw for regulating the reduction valve
R
has already been calibrated
to the optimal pressure setting (approximately 3,5 bar).
In any case, the quantity of gas supplied can be increased by turning the
screw in the clockwise direction, or decreased by turning it in the anti-clock-
ZLVH GLUHFWLRQ ¿J 5HFKDUJHDEOH &2
2
cylinders can charge approxi-
mately 140 liters of water.
NOTICE! Rechargeable cylinders are empty when supplied. Have
WKHF\OLQGHU¿OOHGZLWKJDVE\WKHQHDUHVWDXWKRUL]HGGLVWULEXWRU
Ask only for CO2 (carbon dioxide) for “food products.”
GB
To start the carbonation device:
Press the pushbutton for carbonated water
.
/HWDIHZOLWUHVRIZDWHUÀRZXQWLOFDUERQDWHGZDWHUEHJLQVWRFRPHRXW
Attention!
The results of pressure variations on carbonation will only have
effect when at least 2 litres of water have been drained off.
Advice on using the appliance for carbonated water
To guarantee the correct operation of the pump in time, the appliance
must always be operated with water in the cooling circuit.
,I PDLQV ZDWHU LV LQVXI¿FLHQW D SURWHFWLRQ V\VWHP LQWHUYHQHV DQG
blocks pump functioning (the NO WATER warning light is illuminated)
To restore functioning the apparatus must be disconnected from the
HOHFWULFDOQHWZRUNDQGUHFRQQHFWHGZKHQWKHUHLVVXI¿FLHQWZDWHULQ
the mains system.
13
Summary of Contents for COSMETAL H2OMY IN F
Page 9: ...HANDBOOK SECTION II 5HVHUYHG WR TXDOL HG RSHUDWRUV 9 ...
Page 21: ...21 ...