Web
Network Keyboard User Manual -20
6
Web
6.1
Web Access
In order to view the keyboard from a network it may be connected to a LAN or internet. The
network setup should be done accordingly.
①
The keyboard shall be powered on and connected to the network. Please see 2.5 Local IP
Setup
for details.
②
Set the local IP address and HTTP port. The default local IP address is 192.168.001.201
and the default HTTP port is 4000. You shall add the port number when typing IP address
in IE address blank as http://192.168.001.201:4000 into IE browser.
③
Enter the password in the subsequent window (the default password is 8888).
Please make sure the IP address of the IE client is in the same local network as that of
the keyboard. If the IP address of the keyboard is 192.168.001.201, the IP address of the
IP client must be 192.168.001.XXX.
Some models may be searched by IP-Tool. Make sure the PC and keyboard are
connected to the LAN and double click the IP-Tool icon to run this software. Then the
keyboard can be searched; if the keyboard can’t be searched, please check whether the
PC and the keyboard are connected to the network or not. Double click the keyboard in
IP-Tool and the system will pop up the IE browser to connect to the keyboard.
You can check the system information. Click “logout” in the top-right corner and log out the
IE client.