background image

Introduction

The DSC Meridian photoelectric smoke detector incorporates
many advanced design features to provide years of reliable
operation. It is important to follow the installation and operation
instructions on this sheet to ensure that the unit will function
properly — even the best designed smoke detector will be rendered
useless if it is not connected or located properly.
It is very important that you understand how to test and maintain
your system. Read the instruction or user manual for your alarm
system to familiarise yourself with the fire alarm functions. Be sure
to test your system regularly following the test procedures described
in your manual. If you should ever have problems operating or
testing your system, and especially if there are problems with the
fire alarm functions, contact your smoke detector installer or
dealer immediately for service.
While smoke detectors and alarm systems are designed to warn you
of potentially dangerous situations, no system can prevent emergencies.
An alarm system is not a substitute for life and property insurance; you
should always maintain appropriate insurance coverage.

How the Smoke Detector Works

As shown in the illustration, a light source is directed across the
smoke chamber and is not normally reflected into the sensing
element. When smoke enters the chamber, the light beam is
scattered by the smoke and is reflected into the sensor. When
enough light is detected by the sensor, an alarm is activated. On
alarm, the sounder is activated and the red LED will flash. 

When

the smoke clears from the smoke chamber, the unit will
automatically reset itself.

Alarm Indications

Condition

Sounder

Indicator

RF

Light

Transmission

No smoke

Silent

Flash every

Supervision

40-50 s

transmission

 every 12 min.

Smoke

Alarm

Flash every

Alarm

0.67 s

transmission

Automatic self test

Silent

Flash every

Supervision

functioning normally

40-50 s

 transmission

every 12 min.

Automatic self test

Chirp between

Flash every

Fire Trouble

insufficient  sensitivity

 LED flashes

40-50 s

transmission

Push-button test

Alarm

Flash every

Supervision

functioning normally

0.67 s

transmission

every 12 min.

Push-button test

Silent

Flash every

Fire Trouble

insufficient sensitivity

40-50 s

 transmission

Magnet/reed switch

Alarm

Flash every

Alarm

test functioning normally

0.67 s

transmission

Magnet/reed switch

Silent

Flash every

Fire Trouble

test insufficient

40-50 s

transmission

sensitivity

Low battery

Chirp simultaneous

Flash every

Fire Trouble

with LED flash

40-50 s

transmission

READ THIS INSTRUCTION SHEET THOROUGHLY BEFORE

INSTALLING AND USING YOUR MERIDIAN SMOKE DETECTOR

Features

• Advanced 90° photoelectric detection pattern and specially

designed smoke chamber

∗∗∗∗∗

 for superior detection and dust

resistance

• Unique high signal-to-noise ratio and superior RFI

immunity to prevent false alarms

• Excellent smoke access provides reliable detection for all

smoke flow directions and velocities

• Loud 85dB piezoelectric alarm horn

• Battery-powered design for easy installation and

independence from house power sources

• Uses six AA batteries and special circuit design to provide

extra long battery life

• Solid-state LED indicator light (red)

• Visible flash light and audible trouble chirp for low battery

warning

• Equipped with an RF transmitter, WLS906 can

communicate with DSC's UL listed, compatible 900 MHz
Wireless Security Systems

• Test button allows user to perform sensitivity test and get

a local indication of test result

• Magnet-activated/reed switch allows user to perform

system test

• Battery removal sensor alerts user to missing battery and

prevents installation of detector when no battery is
installed

• Automatic self-test once every 40 seconds provides an

audible trouble indication if the unit has insufficient smoke
sensitivity

• Attractive styling for any decor

• This symbol on the nameplate means the product is

listed by Underwriters Laboratories Inc. (UL
Standard 217, Single and Multiple Station Smoke
Detectors).

∗∗∗∗∗

 Protected under Canadian Patent No. 1452296. Other patents pending.

WLS906

Battery-Powered Smoke Detectors
For Residential Use

INSTRUCTIONS FOR
INSTALLATION AND USE