600.100UK
MTM01 User Manual
Multimeter comparison table
Model
DCV
ACV
DCA
ACA
Ω
hFE
Cap
MTP01
Y
Y
Y
Y
Y Y
Y
Y
Y
Technical Specifications
Accuracies are guaranteed for 1 year, 23ºC ± 5ºC, less than 80% RH.
DC Voltage
RANGE
RESOLUTION
ACCURACY
200mV
100uV
±(0.5% of rdg + 3D)
2V
1mV
20V
10mV
±(0.8% of rdg + 5D)
200V
100mV
600V
1V
±(1.0% of rdg + 5D)
Input Impedance: 10MΩ
Overload Protection: 1000V DC or 750V AC rms
Max. Input voltage: 1000V DC
AC Voltage
RANGE
RESOLUTION
ACCURACY
200V
100mV
±(2.0% of rdg + 10D)
500V
1V
±(2.0% of rdg + 10D)
Input Impedance: 10M
Ω
Frequency Range: 40Hz ~ 400Hz
Overload Protection: 1000V DC or 750V AC rms
Response: Average, calibrated in rms of sine wave
Max. Input voltage: 750V AC rms