![Mercury/Mariner 25 MARATHON Manual Download Page 107](http://html.mh-extra.com/html/mercury-mariner/25-marathon/25-marathon_manual_1773731107.webp)
Section 6 - Storage
90-8M0074347
eng
OCTOBER 2012
Page 99
Draining the Seawater System
!
CAUTION
Water can enter the bilge when the drain system is open, damaging the engine or causing the boat to sink. Remove the boat
from the water or close the seacock, disconnect and plug the seawater inlet hose, and ensure the bilge pump is operational
before draining. Do not operate the engine with the drain system open.
IMPORTANT: Only drain the seawater section of the closed cooling system.
IMPORTANT: The boat must be as level as possible to ensure complete draining of the cooling system.
IMPORTANT: The engine must not be operating at any point during the draining procedure.
Draining the 3.0 MPI ECT Seawater System
Single‑Point Drain System
!
CAUTION
Disconnecting the blue drain hoses can cause serious burns due to hot water. Check all hose connections before operating
the engine and never disconnect the hoses until the engine has had suffient time to cool.
NOTICE
If the boat is at rest in the water with the engine off, an open seacock or water inlet hose could introduce water into the
engine's cooling system or the boat. Keep the seacock or water inlet hose plugged until ready to start the engine. Attach a
tag to the ignition switch or steering wheel to inform others of the water inlet connection.
IMPORTANT: Do not start or operate the engine at any point in this procedure.
1. If draining with the boat in the water, close the seacock '(if equipped) or remove and plug the water inlet hose. If draining
with the boat out of the water, place it on a level surface to drain completely.
2. Turn on the bilge pump.
3. Push the quick connect fitting release buttons and remove the blue drain hoses from the bracket.
a -
Release button (to engine block)
b -
T‑handle
c -
Release button (to exhaust manifold)
d -
Blue drain hoses
e -
Hose guide
4. Pull the T‑handle until the hose guide is in contact with the quick connect fittings.
5. Push down on the T‑handle to force the blue drain hoses below their connection points on the block.
6. If water does not drain from all blue drain hoses, refer to
Clearing Clogged Drain Hoses
.
7. Leave the blue drain hoses disconnected until all water drains from the engine.
8. Pull the T‑handle until the quick connect fittings on the blue drain hoses are within reach.
9. Install the quick connect fittings on the bracket. Pull on the blue drain hoses to ensure they are firmly connected.
10. Push down on the T‑handle until seated.
11. Turn off the bilge pump.
12. If the boat was drained in the water, open the seacock, if equipped, or unplug and reconnect the water inlet hose prior to
operating the engine.
IMPORTANT: The next time you start the engine, check the blue drain hoses for leaks.
32559
b
c
d
e
a