![Mercedes-Benz Metris BM 447 Body & Equipment Manualline Download Page 53](http://html1.mh-extra.com/html/mercedes-benz/metris-bm-447/metris-bm-447_body-and-equipment-manualline_1772311053.webp)
Mercedes-Benz Body & Equipment Guideline for Metris - BM 447, Version November 27, 2015.
!
Please observe the revision notes compared to 09/18/2015 ! Only print out complete sections of the current version!
53
5.5 Threshold values for electrics/electronics
5 Technical threshold values for planning
5.5
Threshold values for electrics/electronics
i
Additional information
Also see chapter 9 “Electrical system”
(
5.5.1 Electric wiring/fuses
The following table is valid for cables with an operating
temperature limit of more than 105 °C = 189 °F for the
insulation.
Max. perma-
nent current
[A]
Fuse rating [A]
Line
cross-section
[mm
2
]
0 - 4.9
5
0.5
5 - 9.9
10
1
10 - 18
20
2.5
19 - 28
30
4
29 - 35
40
6
36 - 48
50
10
49 - 69
70
46
70 - 98
100
25
99 - 123
125
35
124 - 148
150
50