X
Unscrew fasteners
:
.
X
Slide cap
=
to the side and remove cover
;
.
When the fuel pressure has been built up using
hand pump
:
on the main filter, you must start
the engine within approximately five seconds.
Otherwise, the fuel pressure decreases and you
will have to repeat the procedure.
X
Push hand pump
:
on engine control unit
;
repeatedly (approximately 100 times), until
you hear the overflow valve open.
X
Press the external engine start/engine stop
page 376) within approximately five
seconds and start the engine.
X
If the engine starts: leave the engine running
at an increased engine speed.
X
If the engine does not start: repeat the pro-
cedure.
X
Tilt the cab forwards (electrohydraulic
page 374) or mechanical hydraulic
X
Tighten the fuel tank filler cap.
X
Replace the cover.
Bleeding the fuel system without fuel
prefilter on chassis frame
(OM 470/471/473 only)
!
Do not bleed the fuel system with several
starting procedures. You could otherwise
damage the starter motor.
X
Apply the parking brake.
X
Switch the ignition lock to the drive position.
X
Shift into neutral.
X
Tilt the cab forwards (electrohydraulic
page 374) or mechanical hydraulic
X
Unscrew the fuel tank filler cap.
X
Remove bolts
;
.
X
Remove cover
:
.
When the fuel pressure has been built up using
hand pump
=
on the main filter, you must start
the engine within approximately five seconds.
Otherwise, the fuel pressure decreases and you
will have to repeat the procedure.
X
Press the handle of hand pump
=
on the
main filter until there is noticeable resistance.
X
Press the external engine start/engine stop
page 376) within approximately five
seconds and start the engine.