INFORMATION FOR LICENSED ELECTRICIAN AND FAN
OWNERS
8
REV 1.0
Please read fault finder before calling for warranty.
1.
FAN WILL NOT START
I.
Check that mains circuit breakers are in the ON position.
II.
Check that isolation wall switch is in the ON position.
III.
Check that speed control knob/pull chain is NOT in the OFF position.
IV.
Check that reverse control switch (if any) is FULLY turned to up (left) or down (right) position.
V.
Check that batteries in the remote handset (if any) are in good condition.
VI.
Check that transmission code setting (if any) on remote control handset and receiver is identical.
VII.
Check that live, neutral, ground and light (if any) wires from isolation wall switch, remote receiver (if any)
through to fan are all wired correctly is accordance with wiring diagram.
VIII.
Check that all wire connections at wall switch, wire connector and/or terminal block are secured (not
loosened).
2.
FAN SOUNDS NOISY.
I.
Check suggested bulbs and fully tighten light fitting (if any).
II.
Re-tighten all screws on fan blades (do not over tighten).
III.
Re-tighten all screws in the hanging bracket and covering plate.
3.
MECHANICAL NOISE
I.
Let the fan run for about 8 hours for settling in period.
4.
FAN TURNS BUT DOES NOT MOVE MUCH AIR
I.
The fan may be running in reverse (for fans with reverse running option).
II.
The distance from the ceiling to the fan blades is too small.
III.
The room may contain items which obstruct the air flow.
IV.
The fan may be too small for the size of the room.