30
7. Maintenance
T
T
DANGER
Electric shock hazard when devices are damaged
Use of a damaged device may result in electric shock.
f
Do not use the device if it is damaged.
f
Mark the damaged device to ensure that no one contin-
ues using it.
f
Eliminate damage immediately.
f
Stop the device if necessary,
Recommended maintenance intervals
Testing intervals of charging infrastructure for electric vehi-
cles based on DGUV (German Social Accident Insurance)
regulation 3.
Component
Maintenance work
Person
responsible
Daily / At every charging
Device
Visual inspection
for defects
User / Owner
Control of opera-
tional readiness
Owner
Every 6 months
Residual cur-
rent device
Function check
Operator / electri-
cian
Charging
cable
Repeat the meas-
urements and tests
according to VDE
0701/702
Electrician
Once a year
Device
Repeat the meas-
urements and tests
according to VDE
0105-100
Electrician
f
Document maintenance sufficiently.
f
If necessary, request maintenance protocol from
MENNEKES support.
Î
A maintenance contract ensures a regular check.
6.7.2 Connection to the device
Automatic connection
f
Open MENNEKES Charge APP.
f
Tap “Search for Wallbox” to find the devices on your
network.
f
If the desired device has been found, select it using the
serial number (SNR) (setup data sheet).
f
Enter PIN1 (APP PIN) of the device and change the
name if necessary.
f
Confirm the entry with “Save”.
Manual connection
In rare cases, the device will not be detected automatically.
You can then connect the device manually.
f
Touch “Set up manually”.
f
Enter the IP address and the respective PIN1 (APP PIN)
of the device and change the name if necessary.
IP address as access point: 172.31.0.1
IP address for integration in the home network: depend-
ing on configuration
Î
“6.3.2 Integrating into the home network”
f
Confirm the entry with “Save”.