8
AA-11-378 CO-AXIAL VENT KIT
AA-11-377 CO-LINEAR VENT KIT
FIGURE 4
NOTE: THE INSERT IS DESIGNED, TESTED & LISTED FOR OPERATION ONLY WITH MENDOTA
INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3, 3A, 4 & 4A.
11.
(See FIGURE 4A) The vent kits include a trimable flashing. Measure, trim and shape flashing to fit the
existing flue liner. This flashing prevents water and small animals from entering area between the chimney liner
and flue liner. Plan for 1” to 1-1/2” (25 mm to 38 mm) overlap on each side. Center the flashing and mark it
about 3" (75 mm) larger in each dimension than the existing chimney. Trim the notch with snips and bend edges
with hand seaming tool, metal break or pliers.
FIGURE 4A: Chimney Flashing and cap
FIGURE 3A CO-LINEAR VENT KIT (Typically for masonry fireplaces.)
NOTE: Either vent kit may be used in any chimney if damper area size permits
.
f i r e - p a r t s . c o m
Summary of Contents for SEABROOK D-40
Page 27: ...26 fire parts com...
Page 37: ...36 Figure 19 fire parts com...
Page 41: ...40 NOTES fire parts com...
Page 42: ...41 NOTES fire parts com...