MENDOTA BLOWER & BURNER REMOVAL & INSTALLATION
BURNER
AIRBOX
REMOVABLE
BURNER PAN/
VALVE ASSEMBLY
BLOWER
ASSEMBLY
NOTE: THE BURNER AND OTHER PARTS SHOWN ABOVE ARE FOR REPRESENTATION PURPOSES ONLY AND
MAY NOT EXACTLY DEPICT WHAT IS INCLUDED IN YOUR FIREPLACE.
BLOWER OPERATION
The Mendota DXV Fireplace is designed so the blower operates at all times the fireplace is operating. The blower output can be
regulated with the rheostat (included), but it must be "on" at all times the burner is "on". NOTE: There will be a time delay in
blower operation during "heat-up" (approx. ½ hour) and extended blower operation during "cool-down" of unit. (Approx. ½ hour)
NOTE: Power supply to blower must be continuous. DO NOT use switch or variable control in power supplied to fireplace.
OPERATION DURING POWER OUTAGE
: As the blower will be inoperable during power outages, it is required that any
upper screen grills, louvers, Filigree fascia or screened doors be removed or opened to provide adequate convective air flow.
BLOWER WIRING DIAGRAM