Getting Started
Page 16
»
Fasten the HDD/SSD to the board from the bottom side with two M3x8 TX8 socket
head screws (position highlighted in red in the following drawing).
»
Secure the HDD/SSD additionally by fixing it to the guide rail with a M3x6 TX8 screw.
»
Apply thread locker to ensure the screws are not loosened by vibrations.
2.2
Removing an SSD/HDD
»
Power down your system and remove the carrier board from the system.
»
Remove the screws holding the drive in place.
»
Unplug the drive from the carrier board’s connector.
2.3
Integrating the Board into a System
You can use the following check list when installing the board in a system for the first
time and with minimum configuration.
»
Set the hex switch to the required position.
»
Power-down the system.
»
Insert the G503 into a peripheral slot of your CompactPCI Serial system, making
sure that the backplane connectors are properly aligned.
Note: The peripheral slots of every system are marked by a circle with a plus sign behind
it on the backplane and/or at the front panel:
»
Power-up the system.
»
Wait until the board has finished initialization and the LEDs stop blinking.
»
Power-down the system.
»
Remove the board from the system.
»
Set the hex switch to position 4.
»
Reinsert the board into the system.
»
Power-up the system.
See
Table 2, RAID switch positions on page 19
.