13
Access level 1
or 2
will be granted.
To leave the menu, use the
button.
Operation
InfOrMATIOn!
If the touch pad is not touched for two minutes,
the access level rights will be automatically
withdrawn.
i
Configuration menu
Number of teeth on the toothed belt pulley of the
MRA 2 motor (1), the default value is 30.
Number of hollow shaft encoder revolutions per
machine revolution, i.e. the ratio between the machine
cylinder and the hollow shaft encoder (2).
InfOrMATIOn!
Enter the ratio on the system before you install
the unit (see the section Setting the hollow shaft
encoder ratio).
Number of pulses per hollow shaft encoder revolution
(3). Take the value from the hollow shaft encoder;
the default value is 2000.
Enter the values using the touchpad (4).
CAuTIOn!
In the interests of your own safety, please
enter all the necessary data on the GT3
console.
1
2
3
!
i
4