Meltem Wärmerückgewinnung GmbH & Co. KG

Am Hartholz 4 · D-82239 Alling

[email protected] · www.meltem.com

VENTILATION THE RIGHT WAY

V E N T I L AT I O N   &   H E AT   R E C O V E R Y

INST

ALLA

TION MANUAL

HOME VENTILATION WITH HEAT RECOVERY

M-WRG-S/Z-T(-F, -FC) and 

InControl pushbutton sensor

Connecting the ventilation unit M-WRG-S/Z-T(-F, -FC)  

to the InControl pushbutton sensor

Part no. 5301-09-01 Week 50/2015 EN

CO²     

Summary of Contents for InControl

Page 1: ...eltem com VENTILATION THE RIGHT WAY VENTILATION HEAT RECOVERY INSTALLATION MANUAL HOME VENTILATION WITH HEAT RECOVERY M WRG S Z T F FC and InControl pushbutton sensor Connecting the ventilation unit M WRG S Z T F FC to the InControl pushbutton sensor Part no 5301 09 01 Week 50 2015 EN CO ...

Page 2: ...l assignment 5 4 1 Board with terminal blocks 5 4 2 InControl pushbutton sensor 6 4 2 1 Back panel with terminal blocks 6 4 2 2 Connection diagram 6 5 Connecting one ventilation unit 7 5 1 Connecting the InControl pushbutton sensor to the M WRG S Z T ventilation unit 7 5 2 Connecting the InControl pushbutton sensor to the M WRG S Z T F ventilation unit 8 5 3 Connecting the InControl pushbutton sen...

Page 3: ...aretaker or property manager These instructions are part of the product Keep the instructions in a safe place for future reference WARNING Follow ALL danger and warning instructions and notes on precautionary measures Read section 2 Safety instructions on page 4 carefully NOTE Also follow the M WRG S M WRG K installation manual part no 5300 10 01 for in stalling the ventilation units 1 2 Descripti...

Page 4: ...en This symbol indicates a list 1 6 Supplementary documents Manual Part no Installation manual M WRG S M WRG K 5300 10 01 2 Safety instructions This manual contains notes that you must follow for your own personal safety and to avoid injury and damage to property They are highlighted by warning triangles and are shown as follows ac cording to the level of danger 2 1 Hazard classification DANGER Th...

Page 5: ... intended use includes compliance with all the notes in the installation manual The ventilation unit must not be operated without a filter For any use contrary to the intended use Meltem Wärmerückgewinnung GmbH Co KG shall accept no liability for any damage that may occur and offers no warranty that the components will work perfectly and correctly 3 Warranty and liability The warranty and liabilit...

Page 6: ...ation guide It is only in this position that the connections on the terminal blocks agree with the connec tions identified in the connection diagram Fig 4 4 2 2 Connection diagram Item Designation 1 Terminal block for pushbuttons 2 Terminal block for LEDs 3 Optional bridge for backlight NOTE The InControl pushbutton sensor has a backlight that can be acti vated if required Place a bridge item 3 in...

Page 7: ...l pushbutton sensor Wire colour Function Pushbutton LED 1 GND GND 2 24 V DC 3 1 Reduced ventilation 4 2 Normal ventilation 5 3 Increased ventilation 6 4 Intensive ventilation 7 1 Reduced ventilation LED 8 2 Normal ventilation LED 9 3 Increased ventilation LED 10 4 Intensive ventilation LED 11 5 Supply air operation 12 6 Exhaust air operation 13 Unused 14 Unused 15 5 Supply air operation LED 16 6 E...

Page 8: ...sensor Wire colour Function Pushbutton LED 1 GND GND 2 24 V DC 3 1 Reduced ventilation 4 2 Normal ventilation 5 3 Increased ventilation 6 4 Intensive ventilation 7 1 Reduced ventilation LED 8 2 Normal ventilation LED 9 3 Increased ventilation LED 10 4 Intensive ventilation LED 11 6 Supply air operation 12 Unused 13 5 Humidity control 14 Unused 15 6 Supply air operation LED 16 Unused 17 5 Humidity ...

Page 9: ...button sensor Wire colour Function Pushbutton LED 1 GND GND 2 24 V DC 3 1 Reduced ventilation 4 2 Normal ventilation 5 3 Increased ventilation 6 4 Intensive ventilation 7 1 Reduced ventilation LED 8 2 Normal ventilation LED 9 3 Increased ventilation LED 10 4 Intensive ventilation LED 11 Unused 12 Unused 13 5 Humidity control 14 6 CO2 control 15 Unused 16 Unused 17 5 Humidity control LED 18 6 CO2 c...

Page 10: ...t and InControl pushbutton sensor should be no more than 15 m long Ventilation unit 1 master must always be switched on It gener ates the feedback for the LED on the InControl pushbutton sensor Ventilation units 2 to 5 slaves only respond to switching commands from the InControl sensor NOTE Connect only to the first ventila tion unit master Connect GND to all the ventila tion units master slaves 6...

Page 11: ... 4 4 4 4 3 5 5 5 5 5 4 6 6 6 6 6 5 13 13 13 13 13 6 11 11 11 11 11 GND 1 1 1 1 1 1 7 2 8 3 9 4 10 5 17 6 15 Table 5 Connecting the InControl pushbutton sensor to M WRG S Z T F ventilation units 6 3 Connecting the InControl pushbutton sensor to M WRG S Z T FC ventilation units Terminal blocks InControl pushbutton sensor Number M WRG S Z T FC ventilation unit Pushbutton LED 1 master 2 slave 3 slave ...

Page 12: ...here may nevertheless still be differences so we cannot guarantee complete accuracy The information in this publication is regularly checked and any necessary corrections are made in the subsequent edi tions Copyright Meltem Wärmerückgewinnung GmbH Co KG We reserve the right to make changes Meltem Wärmerückgewinnung GmbH Co KG Am Hartholz 4 D 82239 Alling Germany Tel 49 0 8141 404179 0 Fax 49 0 81...