Table 19 - Troubleshooting
Problem
Indicator
Symptoms
Corrective Measures
LEDs
System Status LED is
blinking for more than 5
minutes
This state means that the MLNX-OS software did not
boot properly and only firmware is running.
To overcome it, connect to the system via the console
port, and check the software status. You might need to
contact an FAE if the MLNX-OS software did not load
properly
System Status LED is red
This state can indicate a number of problems:
• Critical system fault (CPU error, bad firmware)
• Over Temperature
To overcome it:
• Check Environmental conditions (room tempera-
ture)
Fan Status LED is red
This state is indicative of a problem with the FAN.
• Check that the FAN is fully inserted and nothing
blocks the airflow.
• Replace the FAN FRU if needed.
PSU Status LED is red
This state is indicative of a problem with the PSU.
• Check/replace the power cable.
• Replace the PSU if needed.
Summary of Contents for SX1012
Page 35: ...Rev 1 4 38 Mellanox Technologies Figure 24 SFP Removal and Insertion Tool...
Page 54: ...Interfaces Rev 1 4 57 Mellanox Technologies Figure 36 Pull out Tab...
Page 76: ...Rev 1 4 111 Mellanox Technologies 5 6 45 C 113 F 8 3 7 8 9 10 11 12...
Page 79: ...Rev 1 4 114 Mellanox Technologies 3 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 PSU InfiniBand...
Page 92: ...Rev 1 4 127 Mellanox Technologies 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...