![Mellanox Technologies SX1012 User Manual Download Page 51](http://html1.mh-extra.com/html/mellanox-technologies/sx1012/sx1012_user-manual_1768396051.webp)
Rev 1.4
54
Mellanox Technologies
3.3.1.3 Power Supply Status LEDs
Figure 32: Power Status LED
RST
UID
PS2
PS1
There are two power supply inlets in the system (for redundancy). The system can operate with
only one power supply connected. In case the power supply is an FRU, a second power supply
unit can be added to support hot-swap ability. Each power supply unit has a single 2 color LED
on the right side of the unit, that indicates the status of the unit. In SX1024 and SX1400 PS1 and
PS2 are combined into one LED.
Figure 33: Rear Side Panel
OK
!
!
OK
OK
!
!
OK
I2C
Power Supply Unit
The primary power supply (PS) unit is located on the left side and the secondary unit is located
on the right side.
Off
The fan unit is not receiving any
power.
Check that the fan unit is properly and completely
inserted.
Risk of Electric Shock!
With the fan module removed power pins are accessible within the module cavity.
DO NOT insert tools or body parts into the fan module cavity.
Table 14 - Fan Status LED Assignments
LED
Behavior
Description
Action Required
Summary of Contents for SX1012
Page 35: ...Rev 1 4 38 Mellanox Technologies Figure 24 SFP Removal and Insertion Tool...
Page 54: ...Interfaces Rev 1 4 57 Mellanox Technologies Figure 36 Pull out Tab...
Page 76: ...Rev 1 4 111 Mellanox Technologies 5 6 45 C 113 F 8 3 7 8 9 10 11 12...
Page 79: ...Rev 1 4 114 Mellanox Technologies 3 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 PSU InfiniBand...
Page 92: ...Rev 1 4 127 Mellanox Technologies 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...