Planning the system’s placement in the rack
Before mounting the system to the rack, select the way you wish to place the system. Pay atten-
tion to the airflow within the rack cooling, connector and cabling options.
While planning how to place the system, review the following points:
• Make sure the system air flow is compatible with your installation selection. It is import-
ant to keep the airflow within the rack in the same direction.
• In case there are cables that cannot bend within the rack or in case more space is needed
for cable bending radius, it is possible to recess the connector side or the FRU side by 2”
(5.08cm) by optional placement of the system’s rails.
• The FRU side is extractable. Mounting the sliding rail inverted to the system will allow
you to slide the FRU side of the system, in and out.
Mounting the slides to the system
Step 1.
The recession feature is bi-directional, meaning that you can recess the system either back-
ward or forward.
Step 2.
Screw the system slides onto the system. Use 5 flat head 6-32 screws for a short system and
7 screws for a standard depth system to connect each system slide. The recommended tight-
ening torque is 1.5±0.2 Nm.
Summary of Contents for SX1012
Page 35: ...Rev 1 4 38 Mellanox Technologies Figure 24 SFP Removal and Insertion Tool...
Page 54: ...Interfaces Rev 1 4 57 Mellanox Technologies Figure 36 Pull out Tab...
Page 76: ...Rev 1 4 111 Mellanox Technologies 5 6 45 C 113 F 8 3 7 8 9 10 11 12...
Page 79: ...Rev 1 4 114 Mellanox Technologies 3 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 PSU InfiniBand...
Page 92: ...Rev 1 4 127 Mellanox Technologies 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...