![Mellanox Technologies sRB-20210G User Manual Download Page 46](http://html1.mh-extra.com/html/mellanox-technologies/srb-20210g/srb-20210g_user-manual_1768365046.webp)
Version 2.0
Device Configuration
46
Mellanox Technologies
NOTE:
The IP address of the sRB-20210G must be on the same subnet as the sMB card with
which the CLI session is established.
5.2
Resetting the sRB-20120G
5.2.1
Resetting the I/O via the GUI
To reset the I/O:
Step 1
Right-click the sRB-20210G graphical representation either from the switch or zoom view.
Step 2
From the menu, select
Reset 10 GbE Gateway
, the following window is displayed.
Figure
5-3. Resetting the 10 GbE Gateway
Step 3
Click
Yes
to reset the I/O. The I/O is reset.
5.2.2
Resetting the I/O via the CLI
To reset the sRB-20210G from the CLI, run the following command:
sRB-20210G-70b0# reload
Reboot the system?[yes]
The sRB-20120G reboots.
10 GbE initiation after reboot:
R:ISR2004-3916(config-chassis)# io show
slot #3, position #1, Type 10 GbE Gateway
[Initiation mode]
GetCommublic SetCommunity:private
To set the sRB-20210G unit to factory defaults:
In privileged mode, run the following command:
10G-Card#( config-)#factory-default
Factory default reboots the system. Choose Yes/No to perform factory
default? [yes]
After pressing Y, the unit is set to its factory defaults.