Dismantling Guide

 

Rev. 1.0 

 

 

 

 

 

Mellanox Technologies Confidential

 

 

 

6 of 13

 

 

 

1

 

Dismantling Instructions 

This guide provides detailed instructions for dismantling the Mellanox InfiniBand 
switch systems. Follow the instructions in the order they are presented. 

1.1

 

InfiniBand Switch Systems - General 

The  InfiniBand  switch  system  complies  with  the  RoHS  directive  under  the 
exemption known as RoHS-6. 

The last digit of the product part number represents the RoHS type. 

For example  

MIS5022Q-1BR

R

 — the last R = RoHS-6 

 

InfiniBand switch system systems are comprised of:  

 

Cover 

 

Power Supply Unit (PSU) 

 

Harnesses 

 

Fan unit 

 

Main Board 

1.2

 

General Preparations 

The  InfiniBand  switch  system  is  assembled  using  Philips  screws,  and  handles 
with snap in latches for modules. 

To  disassemble  the  InfiniBand  switch  system  you  will  need  a  small  Philips 
screwdriver. 

The pictures displayed in the following pages provide visual guidance explaining 
how to remove the modules from the mechanical base. 

Summary of Contents for MIS5022Q-1BFR

Page 1: ...Document no 3408 Mellanox Technologies Confidential http www mellanox com Dismantling Guide OPNs MIS5022Q 1BFR MIS5022Q 1BRR Rev 1 0...

Page 2: ...E EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Mellanox Technologies Inc 350 Oakmead Parkway Suite 100 Sunnyvale CA 94085 U S A www mellanox com Tel 408 970 3400 Fax 408 970 3403 Mellanox Technol...

Page 3: ...er Supply Unit 8 1 5 Extracting the Fan Unit 10 1 6 Extracting the Board 12 List of Tables Table 1 Revision History 4 Table 2 Switch OPNs for this Procedure 4 Table of Figures Figure 1 Remove the Cove...

Page 4: ...g the requirements of WEEE recycling Intended Audience This manual is intended for technicians who dismantle the switch systems as a reference for WEEE recyclers Mellanox Technologies emphasizes the i...

Page 5: ...the requirements of the European Union s WEEE waste electrical and electronic equipment directive The directive mandates how the materials used in electrical and electronic equipment must be disposed...

Page 6: ...RoHS 6 The last digit of the product part number represents the RoHS type For example MIS5022Q 1BRR the last R RoHS 6 InfiniBand switch system systems are comprised of Cover Power Supply Unit PSU Har...

Page 7: ...Guide Rev 1 0 Mellanox Technologies Confidential 7 of 13 1 3 Cover 1 Unscrew the rear side screws and slide the cover to the back for opening it 2 Slide the top to the rear and lift off Figure 1 Remov...

Page 8: ...e power Supply unit is located on the side of the switch unit next to the main board Figure 2 PSU Location 1 Disconnect the 3 harness connectors from the main board the inlet and the ground Figure 3 H...

Page 9: ...Dismantling Guide Rev 1 0 Mellanox Technologies Confidential 9 of 13 Figure 4 Remove the Power Supply Unit from the Switch...

Page 10: ...anox Technologies Confidential 10 of 13 1 5 Extracting the Fan Unit The Fan unit is located in the rear of the system Figure 5 Fan Location 1 Disconnect the 3 harnesses from the fan unit to the board...

Page 11: ...nfidential 11 of 13 2 Disassemble the 2 screws attaching the Fan wall to the bottom of the mechanical enclosure base 3 Disassemble the 4 screws attaching the Fan wall to the rear of the mechanical bas...

Page 12: ...Rev 1 0 Mellanox Technologies Confidential 12 of 13 1 6 Extracting the Board 1 Disassemble the 5 screws and washers attaching the main board to the mechanical base Figure 8 Board Screw Locations 2 Rem...

Page 13: ...Dismantling Guide Rev 1 0 Mellanox Technologies Confidential 13 of 13 3 Unscrew the Heat sink screws to remove the Heat sink Figure 9 Remove Heat Sink...

Reviews: