Installation
Rev 1.1
Mellanox Technologies
39
2.10.1.2 Fan
The system can operate indefinitely with less than a full compliment of fans in the fan modules,
so long as the ambient temperature is below 45° Celsius.
To extract a fan unit:
Step 1.
For a fan unit composed of two fans: using two fingers, push both latch releases towards each
other simultaneously while pulling the fan module out of the system. As the fan unseats, the
Fan Status LED will turn off.
For a single fan unit: grasping the handle with your right hand, push the latch release with your
thumb while pulling the handle outward. As the fan unit unseats, the fan unit status LEDs will
turn off.
Step 2.
Remove the fan unit.
Figure 25: Fan Module Latches
To insert a fan unit:
Step 1.
Make sure the mating connector of the new unit is free of any dirt and/or obstacles.
Step 2.
Insert the fan unit by sliding it into the opening until slight resistance is felt. Continue pressing
the fan unit until it seats completely
Operation without a fan unit should not exceed two minutes.
During fan hot-swap, if the LED indicator is OFF, the fan unit is disconnected.
Make sure that the fans have the air flow that matches the model number. An air flow
opposite to the system design will cause the system to operate at a higher (less than
optimal) temperature.
For power supply unit air flow direction, refer to Section 2.2 on page 15
The green Fan Status LED should light. If not, extract the fan unit and reinsert it. After
two unsuccessful attempts to install the fan unit, power off the
system
before attempt-
ing any system debug.
These two latches must be pushed towards each other at the
same time while the module is pulled out.
Push Here
Push Here
Summary of Contents for MetroX TX6240
Page 8: ...Mellanox Technologies 8 Table 37 RJ 45 CONSOLE Pinout 72 Table 38 RJ 45 I2C Pinout 72...
Page 79: ...Rev 1 1 Mellanox Technologies 79 5 6 7 8 9 10...
Page 80: ...Mellanox Technologies 80 11 12 13 14 15 16...
Page 81: ...Rev 1 1 Mellanox Technologies 81 17 18 19 20 21 WEEE 22...
Page 83: ...Rev 1 1 Mellanox Technologies 83 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Page 96: ...Mellanox Technologies 96 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...