Summary of Contents for InfiniScale MTS3600Q-1UNC

Page 1: ...Mellanox Technologies InfiniScale IV 36 Port QSFP InfiniBand Switch User Manual P N MTS3600Q 1UNC MTS3600Q 2UNC MTS3600R 1UNC MTS3600R 2UNC Rev 1 5...

Page 2: ...970 3403 Mellanox Technologies Ltd PO Box 586 Hermon Building Yokneam 20692 Israel Tel 972 4 909 7200 Fax 972 4 959 3245 NOTE THIS INFORMATION IS PROVIDED BY MELLANOX FOR INFORMATIONAL PURPOSES ONLY...

Page 3: ...pply Unit 14 2 2 5 InfiniBand Cable Installation 15 2 2 6 Extracting and Inserting the Fan Unit 16 2 2 7 Replacing the Battery in the Management Module 16 Chapter 3 Management and Tools Overview 17 3...

Page 4: ...5 added installation instructions added ECM Removed Watermark November 2008 Rev 1 4 fixed weight in specs October 2008 Rev 1 3 Minor Formatting changes September 2008 Rev 1 2 Added Reprogramming the...

Page 5: ...QSFP 20Gb s InfiniBand Switch unless explicitly indicated oth erwise Switch Products Covered in this User s Manual Table 2 Reference Documents Mellanox Firmware Tools MFT User s Manual Document 2329 T...

Page 6: ...configured for standard operation within an InfiniBand fabric and requires an InfiniBand compliant Subnet Manager running from one of the hosts All that is required for normal operation is to follow...

Page 7: ...atus LEDs Figure 2 QSFP Switch System Front and Back Panels All InfiniBand connectivity is via the rear panel All connectors can support active cables 2 1 1 Status LEDs Figure 3 Power and System LEDs...

Page 8: ...lso has three status LEDs on the right side of the PSU that indicate the internal status of the unit AC This LED when lit indicates input voltage between 90 and 264 Volts This LED when lit indicates a...

Page 9: ...e VGA port is for video output from the management module 2 1 3 2 RJ 45 Ethernet Connector The Ethernet connection provides access for remote management The MTS3600 can be connected to an Ethernet swi...

Page 10: ...1 Installation Safety Warnings For Safety Warnings in French see Appendix E on page 32 and for German see Appendix F on page 34 For Special Regulations Regarding Finland Sweden Denmark and Norway see...

Page 11: ...ng 90 264 VAC connections for all possible PSUs Copper InfiniBand cables are heavy and not flexible as such they should be carefully attached to or detached from the connectors Refer to the cable manu...

Page 12: ...the ESD strap is touching your skin and that the other end is connected to a verified ground 2 Choose which way you want the switch to slide out of the rack Either the side with the power supply unit...

Page 13: ...mounting plate There are three sets of holes in the mounting plate to choose from You can choose any of the pairs make sure that you pick the same pair for both mounting plates This allows you to redu...

Page 14: ...witches with only one unit installed a second PSU may be installed at a later time Each supply has a separate AC receptacle The input voltage is auto adjusting for 90 264 VAC 47 63Hz power connections...

Page 15: ...d status indicators Caution When turning off the switch make sure ALL LEDS are off to ensure a pow ered down status CAUTION Risk of electric shock and energy hazard The two PSUs are inde pendent Disco...

Page 16: ...pply connector Note The green PSU indicator should light and the yellow indicator should remain off If not extract the PSU and re insert it again 2 2 5 InfiniBand Cable Installation All cables can be...

Page 17: ...ill remain on 2 Pull the fan unit out by pulling on the thumbscrews As the fan unseats the fan status indicator will turn off To insert a FAN Unit 1 Make sure the mating connector of the new unit is f...

Page 18: ...InfiniScale IV 36 Port QSFP InfiniBand Switch User Manual MellanoxTechnologies Rev 1 5 13 2 2 7 Replacing the Battery in the Management Module TBD Need procedure...

Page 19: ...www mellanox com Downloads InfiniBand SW Drivers You will also need to download and unzip the firmware binary image This is provided in the Mellanox Web site at http www mellanox com Downloads Firmwa...

Page 20: ...e issued I I IPoIB Subnets Check I 32 I skip option set no report will be issued I I Bad Links Info I I No bad link were found I Stages Status Report STAGE Errors Warnings Bad GUIDs LIDs Check 0 0 Lin...

Page 21: ...1UNC_A1 ini PSID MT_0C20110003 I Generating image WARNING Running quick query Skipping full image integrity checks Current FW version on flash 7 0 135 New FW version 7 0 138 Burning second FW image wi...

Page 22: ...ning isw d dev mst mtusb 1 s shark p L1 3 Run the burn command flint d dev mst mtusb 1 i fw IS4 rel 7_0_142 MTS3600Q_A1 bin qq b 4 Power cycle the switch by unplugging and re plugging the power cord t...

Page 23: ...cessed through KVM SSH Telnet the WEB Connection is made through either the video and USB connectors for KVM or the ethernet connector See the Embedded Tools user manual included on the CD for further...

Page 24: ...information 3 3 3 Downloading Firmware Firmware for this switch system can be found at and downloaded from http www mellanox com Downloads Firmware Be sure to read and follow all of the instructions...

Page 25: ...U The power LED for the switch shuts off 1 Check that the there is adequate ventilation 2 Make sure that there is nothing blocking the front or rear of the chassis and that the fan mod ules and ventil...

Page 26: ...InfiniScale IV 36 Port QSFP InfiniBand Switch User Manual MellanoxTechnologies Rev 1 5 21 4 1 Management Module How do I know if the battery is dead 1 Replace the battery...

Page 27: ...on of 40Gb s 20Gb s 10Gb s 8 InfiniBand Virtual Lanes for all ports Baseboard Performance and Device man agement Agents for full InfiniBand In Band Management QDR Safety EMC Emissions Environmental Ac...

Page 28: ...al Lanes for all ports Baseboard Performance and Device man agement Agents for full InfiniBand In Band Management DDR Safety EMC Emissions Environmental Acoustic Sound power level US Canada cTUVus EU...

Page 29: ...ainst harmful interference when the equipment is operated in a commercial environment This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accor dance...

Page 30: ...du Canada 0 1 4 VCCI Statements Japan Class A Statement 0 1 5 Translation This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology E...

Page 31: ...niScale IV 36 Port QSFP InfiniBand Switch User Manual MellanoxTechnologies Rev 1 5 5 Appendix A Switch Hardware Components Fan Unit Primary Power Supply Unit Place for Optional Secondary Power Supply...

Page 32: ...L Module Reset 10 Vcc Rx 3 3 V Power supply receiver 11 SCL 2 wire serial interface clock 12 SDA 2 wire serial interface data 13 GND Ground 14 Rx3p Receiver Non Inverted Data Output 15 Rx3n Receiver I...

Page 33: ...supply blank MTM003600 Rack installation kit MTR003600 Fan Unit for QSFP MTF000960 Power cord Type B for USA Canada Mexico Taiwan ACC000204 Power cord Type H for Israel ACC000205 Power cord Type E F...

Page 34: ...on Le ch ssis ne doit pas tre empil sur un autre mat riel Si le ch ssis tombe il peut pro voquer des blessures corporelles et des d gradations de biens Ce produit comporte un couvercle transparent sur...

Page 35: ...0 Codes lectriques locaux et nationaux Ce mat riel ne doit tre install remplac ou entretenu que par du personnel form et qualifi L limination de ce mat riel doit s effectuer dans le respect de toutes...

Page 36: ...hassis sollte nicht auf andere Ger te gestapelt werden Wenn das Chassis herunt erf llt kann es zu Verletzungen und Besch digungen an Ger ten f hren Dieses Produkt verf gt ber eine Abdeckung ber dem Be...

Page 37: ...ale elektrische Bestimmungen Diese Ger t sollte nur von geschultem und qualifiziertem Personal installiert ausge tauscht oder gewartet werden Die Entsorgung dieses Ger ts sollte unter Beachtung aller...

Page 38: ...Denmark The AC cord shall have an integral ground wire and can only be plugged into a fully grounded outlet Finland Norway Sweden Do not connect this unit to any outlet that is not fully grounded Lai...