![Melitta Cafina XT8 Operating Instructions Manual Download Page 7](http://html1.mh-extra.com/html/melitta/cafina-xt8/cafina-xt8_operating-instructions-manual_1768118007.webp)
•
Do not hold any body parts under the
outlets when hot liquids or steam are
being dispensed. This occurs in the
following situations:
͵
After switching on
͵
When beverages are being dispensed
͵
During automatic cleaning
͵
During rinsing processes (e.g., when
switching off)
•
Do not touch any hot parts.
•
When products are being dispensed,
there is a risk of scalding from the actual
products. Always take care when handling
hot beverages.
•
Take note of any visible damage or mal-
functions. Obvious malfunctions include
water leaks, odors and heat formation,
unusual noises, as well as error messages
on the display. In the event of any unusual
situation:
͵
Disconnect the mains plug
͵
Switch off the water supply
͵
Contact customer service
͵
Have the machine checked and re-
paired by customer service
•
Clean the machine at least once per day,
especially the parts in contact with milk.
Impurities could cause health problems.
•
Comply with all intervals for cleaning,
inspection, and maintenance, as specified
in the instructions. Otherwise, the safety,
functional reliability, and durability may
be impaired.
3
Technical data
Machine specifications
Dimensions (W x D x H)
350 x 580 x 765 mm
Weight
approx. 70 kg
Coffee supply
2 x 3 l / 2 x approx.
1,000 g
Instant supply
1 x 1.7 l / 1 x approx.
1,300 g or 2 x 1.1 l / 2 x
500–850 g
Coffee grounds drawer
capacity
For approx. 40 portions
Operating data
Hourly output
approx. 40 l hot water or
approx. 200 cups of Café
Crème (125 ml)
Permissible ambient
temperature
+ 5-30 °C
Permissible air humidity
< 80 % non-condensing
Connections
Power supply
3N AC 400 V, 50-60 Hz
Power consumption
Maximum 8.7 kW
Fuse protection provided
by customer
3 x 16 A (required)
Connection
1.8 m mains cable with
mains plug (e.g., CEE
16 A)
Fresh water connection
G ¾" outer thread
Fresh water pressure
At least 0.25 MPa
(2.5 bar) at approx. 2 l/
min, a pressure reducer
is required for static
pressures higher than
0.6 MPa (6 bar)
Fresh water carbonate
hardness
1-3 °dKH: no action
required, 4 °dKH and
above: decarbonization
system required (e.g.,
BRITA-Purity), less
than 1 °dKH: consult
manufacturer
Waste water connection
At least DN 25 - NW 1"
Noise level
< 70 dB(A)
Technical data