3. Remove the powder chute (2).
4. Repeat stages 1 to 3 for the second instant container
if necessary.
5. Remove the tube (6) on the mixer housing and on the
beverage outlet.
6. Turn the mixer flange (5) counterclockwise until the
arrow is on the "lock open" symbol.
7. Remove the entire mixer housing (4) towards the
front.
8. Remove the cover (3).
000122
1
2
Fig. 44: Removing the mixer impeller
9. Remove the mixer impeller (1) from the axle either
by hand or using the removal tool (2) provided.
9
The mixer unit has been removed.
Cleaning the mixer unit
1. Remove rough dirt with water and a brush.
2. To clean the mixer unit, proceed with one of the
following options:
•
Clean the parts in a dishwasher at a maximum of
60 °C.
•
Clean all parts thoroughly with hot water and a
cleaner suitable for milk products.
͵
Rinse all parts thoroughly with clean water.
3. Dry the parts completely.
͵
To prevent the instant powder from forming
clumps, the parts must be absolutely dry.
4. Damp-clean the area around the axle.
͵
This is the area where the mixer impeller is locat-
ed.
9
The mixer unit has been cleaned.
Assembling the mixer unit
Assembly is carried out by reversing the order of the
removal process.
000123
1
2
Fig. 45: Fitting the mixer impeller
1. Insert the mixer impeller onto the axle as far as it will
go.
͵
Note that the flattened side (1) matches up with
the arrow (2) on the mixer impeller.
000174
1
12
3
4
5
6
Fig. 46: Mixer unit
2. Re-fit the cover (3).
3. Fit the mixer housing (4).
Cleaning
32
26646 • 20160202
8