MA-5151-ENG
PATTERN CONTROLLER STARBI
INTRODUCTION
2-5
Rear connections StarBi 4-6 Outputs
1. Six inputs for photocells (according to model).
2. Six outputs for activation channels of solenoid valves,
two per channel (according to model).
3. One 0-10 V analogue input for speed reading.
4. Two 0-10 V analogue outputs for regulating pump
pressure or motor speed (one isolated (1) and one
uninsulated (2) that includes a pin with 24V / 100 mA
supply).
5. One input for encoder.
6. Digital inputs (general inhibition and temperature OK).
7. Digital outputs (error and status).
8. An RS485 port with Modbus RTU / Profibus
communication (optional).
1
2
3
4
5
7
6
8