INSTALLATION
3-11
MA-5130-GBR
PS20 NON STOP DRUM UNLOADER INHIBITION MANUAL
External channels inhibition
1. If only this signal will be connected, use a 0.5 mm
2
two-wire cable.
2. Open the door of the electrical cabinet as far as possible. Thread the
power cord (Ø4-8 mm) through the electrical cable gland Pg13, making
sure that the cord reaches the terminal blocks where that signal has to
be connected.
3. Disconnect the jumper cables between terminals
13X31
-
13X32
(inhibition 1) and
13X33
-
13X34
(inhibition 2).
4. Insert the wires in
13X31
-
13X32
(inhibition 1) and/or
13X33
-
13X34
(inhibition 2)
terminals blocks and tighten them with the fixing screws.
Each signal inhibits the following elements:
The terminal block is double so you must to connect every wire in a
free hole of the terminal block. It has no polarity so it doesn’t matter
the place you connect them.
5. Make sure that the cables are firmly attached by the terminal screws.
6. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
Caution:
When the external inhibition is activated, it is not possible to activate
(ON) from the programming screen the different elements of the inhibited
channel group.
Inhibition 1
Inhibition 2
Manifold 1
Swirl 1
Manifold 2
Swirl 2
Hose 1
Applicator 1
Hose 3
Applicator 3
Hose 2
Applicator 2
Hose 4
Applicator 4
Summary of Contents for PS20
Page 18: ...FOCKE MELER GLUING SOLUTIONS 2 8 INTRODUCTION This page is intentionally left blank ...
Page 30: ...FOCKE MELER GLUING SOLUTIONS INSTALLATION 3 12 This page is intentionally left blank ...
Page 56: ...FOCKE MELER GLUING SOLUTIONS 4 26 NAVEGATION SUR L ECRAN TACTILE Cette page n a pas de texte ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 8 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 9 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 10 2 SPARE PARTS LIST This page is intentionally left blank ...
Page 96: ...FOCKE MELER GLUING SOLUTIONS 10 10 SPARE PARTS LIST 3 27 1 2 21 6 10 9 4 7 5 20 22 ...