2.2 Extra Settings
Regrind charger
Channel number
Feeder
Pattern controller
Level detector
Extermal HMI
Wireless communication
PISTÓN
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
START
Network Name
SSID:
0.0.0.0
IP:
Online
Wireless Communication
Channel number
Remote actuation
Remote SW update
Static Configuration
Connection Status
Wireless communication (Wi-Fi)
Optionally, the unit comes equipped with a wireless communication system to
connect to a local network. This system connects the unit to a Meler Services
Platform(*) with the following main functions:
• Monitoring.
Regularly sends the platform’s status and operating data.
The data can be configured according to user needs.
• Actions and Programming.
It is possible to send specific actions or
change the programming of a specific unit.
• Technical support.
The unit provides direct information on its status and
can schedule unit maintenance or keep a log of all interventions done on
it.
(*) Check with the After-Sales Service or your Meler Sales Agent for more
information about this service performance.
Connection configuration
1. Install the ‘Espressif Esptouch’ app on a smartphone device.
2. Connect the device to the local Wi-Fi network where you want to connect
the melter, then run the app.
3. On the melter’s screen, click START to start syncing. Follow the
instructions on the app to configure the melter’s Wi-Fi access.
4. The unit’s screen will show the connection status, the name of the Wi-Fi
network, and the IP address automatically assigned.
You can also configure the following options from this screen:
• Remote control.
Enables the unit to be able to receive actions.
• Remote software update.
Enables the unit to be able to receive software
updates.
• Static configuration.
Enables the configuration of a static IP address for
the melter.
PISTÓN
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
6
2.2 Extra Settings
Regrind charger
Channel number
Feeder
Pattern controller
Level detector
Extermal HMI
Wireless communication
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...