MELTER OPERATION
4-21
MA-5184-ENG
PUR LC/MC ADHESIVE MELTER
1.1 Heating zones
This menu lets you do the following for each zone:
• Change the name to identify it more easily.
• Edit the set point temperature.
• Edit the standby value. The value indicates the temperature reduction
with respect to its set point.
• Apply PID values. By default the unit comes configured with a Standard
PID.
You can select from four PID options: Standard, Moderate, Quick or Ma-
nual.
Note.
The PID values are directly involved in the heating
process. Do not modify these values if you do not have
the required technical knowledge or without the advice of
Meler’s After Sales Service.
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
30
12
300
P:
I:
D:
-60 °C
150 °C
152 °C
PID: Standard
Standby
Temperature:
Real
Set Point
T: Tank
ENGRANE
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
1. Heating
1. Heating
1.1 Zones
1.3 Inhibition
1.4 Auto
Standby - OFF
1.5 Heating
Extra Settings
1.2 Sequential
B
D
A - Configuración de zonas de calentamiento.
B - Configuración de calentamiento secuencial por zonas.
C - Programación de Inhibiciones.
D - Configuración de modos de Standby.
E - Acceso a opciones extra.
‘1. Heating’ Menu
A
C
E
Summary of Contents for Micron PUR LC
Page 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Page 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Page 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Page 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Page 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...