INTRODUCTION
2-3
MA-5052-ENG
MACRO SERIES MELTER MANUAL
Control of internal pumping and external speed_
Switches in the
position ok ‘int’ and ref ’ext’. This mode of operation is performed
through internal pumping control and speed control by means of
an external 0-10 V signal sent from the main machine.
Control of external pumping and internal speed_
Switches
in the position ok ‘ext’ and ref ’int’. This mode of operation is
performed through external pumping control and manual speed
control.
Control of external pumping and speed_
Switches in the position
ok ‘ext’ and ref ’ext’. In this working mode, both pumping and
speed are controlled from the main machine. Speed is controlled
by means of an external 0-10 V signal sent from the main
machine.
Standby mode_
The hot-melt melter remains in a resting state, with
the materials kept at (programmable) temperature values below the
pre-selected value. The pump remains deactivated.
Alarm mode_
The hot-melt melter detects a malfunction and warns
the operator of this event. The pump remains deactivated.
Stop mode_
The hot-melt melter remains off, without heating the
materials and with the pump deactivated. The electrical and pneumatic
supply remains activated between the network and the system,
however.
Hot-melt melter identification
When placing orders for replacement parts or requesting help from our
service center, you should know the model and reference number of your hot-
melt melter.
This and other technical information will be found on the identification plate
located on the side of the lower part of the hot-melt melter.
Summary of Contents for Macro Series
Page 1: ...MA 5052 ENG 221220 GLUING SOLUTIONS ADHESIVE MELTER MACRO SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 32: ...FOCKE MELER GLUING SOLUTIONS 3 12 INSTALLATION This page is intentionally left blank ...
Page 58: ...FOCKE MELER GLUING SOLUTIONS 4 26 MELTER OPERATION This page is intentionally left blank ...
Page 66: ...FOCKE MELER GLUING SOLUTIONS 5 8 MAINTENANCE This page is intentionally left blank ...
Page 71: ...ELECTRICAL DRAWINGS 7 1 MA 5052 ENG MACRO SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 72: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 74: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 8 SPARE PARTS LIST This page is intentionally left blank ...