
4-27
MELTER OPERATION
MA-5127-ENG
MACRO FOAM SERIES MELTER MANUAL
Loader OFF function
If you want to disable the automatic pellet feeder, push and hold the OFF
button for 3 seconds. The warning light will start to flash slowly. If you want to
activate loading, push the lit “RESET” button and loading will be reactivated.
OFF mode resets all existing alarms (if it goes into OFF mode with the open lid
alarm activated, when loading is activated and if the lid is still open it will wait
the programmed time to activate the open lid alarm).
Colourless warning light
If the equipment has the warning light optional feature, the colourless warning
light statuses are as follows:
1. OFF: the equipment’s level is high enough.
2. Steady on: the equipment is loading (EV= ON)
3. Very slow flashing: load blocked status
4. Fast flashing: error status.
Low level detection
Launching the feeder
Stopping the feeder
System refilled
Detection of the correct level
Start of the over-level timing
Summary of Contents for MACRO FOAM Series
Page 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Page 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...