10.Specifications
10-1.General Specifications
DC+24V
*1 (Ripple voltage P-P 2.0V or less)
● Rated input current :
〔DRIVE I.SEL ⇒ No.F set up〕
at DRIVE
DC+24V: 1.7A
*2
● Rated input current :
〔HOLD I.SEL ⇒ Approx. 40% set up〕
at HOLD
DC+24V: 0.4A
●DRIVE CURRENT
0.38A/phase~1.50A/phase
●HOLD CURRENT
Approx. 40% of DRIVE CURRENT
(factory-set)
●Drive pulse input
(CW, CCW)
Photo-coupler input
●Motor excitation stop input
(M.F)
Photo-coupler input
●Phase signal output
(P.O)
O/C output
●Overheat alarm output
(O.H.A)
O/C output
●HOLD CURRENT selection
(HOLD I.SEL)
●DRIVE CURRENT selection
(DRIVE I.SEL)
●STEP TABLE selection
(S.T SEL)
●STEP ANGLE selection
(STEP SEL)
●HOLD SWITCHING TIME selection
(DHT SEL)
●PULSE INPUT TYPE selection
(SPI SEL)
Indoor (Exposure to direct sun is not allowed.)
Without any explosive, corrosive or inflammable gas, oil mist,
or dust.
*1
Input voltage range is DC+24V±10%.
*2
Use a power supply that provides sufficient input current.
Up to 1000 m above sea level.
(No freezing allowed.)
(No condensation allowed.)
(No freezing allowed.)
0℃ ~ +40℃
80%RH or less
-10℃ ~ +55℃
80%RH or less
(No condensation allowed.)
No abnormality should be found after a vibration test
at 10~55Hz, 0.15mm P-P
Exterior Dimensions
Weight
Withstanding
Vibration
Insulation resistance
H
75 ×
W
58 ×
D
32 (mm)
0.11 kg
DC connector - signal connector - Frame
(Each other)
DC500V 100MΩ or more
Operating Ambient
Humidity
Storing Temperature
Storing Humidity
Atmosphere
Altitude
Output Signal
Operating Ambient
Temperature
Supply Power
Functions of
Operating Sections
Motor output
current
Input Signal
-29-
Summary of Contents for ADB-2F30BA
Page 30: ...ADB 2F30BA Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 30 ...
Page 35: ...ADB 2F30BA Instructions Manual 10 3 Dimensions Unit mm 35 ...
Page 38: ...ADB 2F30BA Instructions Manual 38 ...
Page 39: ...ADB 2F30BA Instructions Manual 39 ...
Page 40: ...ADB 2F30BA Instructions Manual 40 ...