6 LANTIME M400 Connectors
6.1 Power Connector
Connector Type:
5-pol. DFK
Pin Assignment:
1: N/-
2: not connected
3: PE (Protective Earth)
4: not connected
5: L/+
Input Parameter
——————————————————————————
Nominal voltage range:
U
N
=
100-240 V
∼
100-240 V
Max. voltage range:
U
max
=
90-264 V
∼
100-250 V
Nominal current:
I
N
=
0.40 A
∼
Nominal frequency range:
f
N
=
50-60 Hz
Max. frequency range:
f
max
=
47-63 Hz
Inrush current:
I
P
=
20 A @ 230 V AC
Output parameter
——————————————————————————
Max. power:
P
max
=
40 W
Max. heat emisson:
E
therm
=
144.00 kJ/h (136.49 BTU/h)
L/+
N/-
100-240 V , 50-60 Hz
100-240 V /
1
2
3
4
5
WARNING!
This equipment is operated at a hazardous voltage.
Danger to life due to electrical shock!
- Only qualified personnel (electricians) may connect the device.
- Never work with open terminals and plugs while the power is on.
- All connectors must be protected against touching live parts with
a suitable plug housing!
- Note: Always ensure safe wiring!
- Important: The device must be connected to a proper grounding (PE).
LANTIME
Date: 1st March 2021
21