![Meinberg IMS-M4000 Manual Download Page 10](http://html.mh-extra.com/html/meinberg/ims-m4000/ims-m4000_manual_1766295010.webp)
2 Safety instructions for building-in equipment
2.5 Replacing the Lithium Battery
Skilled/Service-Personnel only: Replacing the Lithium Battery
The life time of the lithium battery on the receiver boards is at least 10 years. If the need arises to replace the
battery, the following should be noted:
There is a Danger of explosion if the lithium battery is replaced incorrectly.
Only identical batteries or
batteries recommended by the manufacturer must be used for replacement.
The waste battery has to be disposed as proposed by the manufacturer of the battery.
2.6 Grounding connection M4000
To ensure a safe operation and to fulfil the require-
ments in accordance with IEC 60950-1, the system must
be correctly connected to an equipotential grounding
bus. On the upper left side of the chassis a ground-
ing connector is provided. The mounting components
(without a cable) are included.
1: Screw M4x6
2: Tooth washer M4
3: Plain washer M4
4: Ring or fork lug
5: Nomel washer
Note:
Use a grounding cable with >= 1,5mm
2
Please ensure a correct crimp-connection!
IMS-M4000
Date: 21st August 2019
5