Format of the Meinberg Capture String
The Meinberg Capture string is a sequence of 31 ASCII characters terminated by a
CR/LF (Carriage Return/Line Feed) combination. The format is:
CH
x_tt.mm.jj_hh:mm:ss.fffffff
<CR><LF>
The letters printed in
italics
are replaced by ASCII numbers whereas the other charac-
ters are part of the time string. The groups of characters as defined below:
x
0 or 1 corresponding on the number of the capture input
_
ASCII space 20h
dd.mm.yy
the capture date:
dd
day of month
(01..31)
mm
month
(01..12)
yy
year of the century
(00..99)
hh:mm:ss.fffffff
the capture time:
hh
hours
(00..23)
mm
minutes
(00..59)
ss
seconds
(00..59, or 60 while leap second)
fffffff
fractions of second, 7 digits
<CR>
Carriage Return, ASCII code 0Dh
<LF>
Line Feed, ASCII code 0Ah