2.4 Fuse Replacement
WARNING!
This equipment is operated at a hazardous voltage.
Danger to life due to electrical shock!
-
Disconnect the device from the mains! To do this, press the disconnector
(switch). Then, loosen the locking screws of the supply plug (if present)
and pull it off.
-
Disconnect all signal lines such as, antenna, fault message relay contact
and serial interfaces from the device.
-
Replace the fuse.
-
Reconnect all cables in reverse order. If necessary, turn on the power again.
Example of fuse marking:
T 2.5 A H 250 V
Trigger Characteristic:T (slow)
Nominal Current A:
2.5 Ampere
Switching Capacity:
H (high)
max. Voltage:
250 V
AC Power Supply
DC Power Supply
Have the spare fuse ready, pay attention to the
correct rated current, characteristics and type.
Important: The fuse must be approved for
operation at (AC) voltage!
Have the spare fuse ready, pay attention to the correct
rated current, characteristics and type.
Important: The fuse must be approved for DC operation!
Fuse Type:
T
Current
A /
Voltage
V in accordance with IEC 60127
with or without extinguishing agent
T = Time-lag / SB = SlowBlow
Fuse Type:
T
Current
A /
Voltage
V in accordance with IEC 60127
with extinguishing agent
T = Time-lag / SB = SlowBlow
Dimensions:
5 x 20 mm
Dimensions:
5 x 20 mm
8
Date: 5th November 2019
GPS165XHS
Summary of Contents for GPS165
Page 1: ...MANUAL GPS165XHS DIN Rail GPS Receiver 5th November 2019 Meinberg Funkuhren GmbH Co KG...
Page 2: ......
Page 25: ...5 GPS165 Features 5 4 4 IRIG Standard Format GPS165XHS Date 5th November 2019 21...
Page 26: ...5 4 5 AFNOR Standard Format 22 Date 5th November 2019 GPS165XHS...
Page 62: ......