Page 26
9 Technical Specications GPS164DAHS
9.2.2 Format of the Meinberg GPS Time String
The Meinberg Standard Time String is a sequence of 36 ASCII characters starting with the STX (start-of-text)
character and ending with the ETX (end-of-text) character. Contrary to the Meinberg Standard Telegram the
Meinberg GPS Timestring carries no local timezone or UTC but the direct GPS time without conversion into
UTC. The format is:
<STX>D:tt.mm.jj;T:w;U:hh.mm.ss;uvGy;lll<ETX>
The letters printed in italics are replaced by ASCII numbers whereas the other characters are
part of the time string. The groups of characters as dened below:
<STX>
Start-Of-Text (ASCII code 02h)
tt.mm.jj
the current date:
tt
day of month (01..31)
mm month
(01..12)
jj
year of
the century
(00..99)
w
the day of the week (1..7, 1 = monday)
hh.mm.ss
the current time:
hh
hours
(00..23)
mm minutes
(00..59)
ss
seconds
(00..59, or 60 while leap second)
uv
clock status characters:
u:
'#'
clock is running free (without exact synchr.)
' '
(space, 20h)
clock is synchronous (base accuracy is reached)
v:
`*'
receiver has not checked its position
` `
(space, 20h)
receiver has determined its position
G
time zone indicator 'GPS-Time'
y
anouncement of discontinuity of time, enabled during last hour
before discontinuity comes in eect:
`A'
announcement of leap second insertion
` `
(space, 20h) nothing announced
lll
number of leap seconds between UTC and GPS-Time
(UTC = GPS-Time + number of leap seconds)
<ETX>
End-Of-Text, (ASCII Code 03h)
26
Date: 27th January 2016
GPS164
Summary of Contents for GPS164-LQ/PPFO-3/REL-1/DAHS
Page 1: ...MANUAL GPS164 PPFO 3 REL 1 DAHS 27th January 2016 Meinberg Radio Clocks GmbH Co KG ...
Page 2: ......
Page 6: ...Page 2 1 General Details 2 Date 27th January 2016 GPS164 ...
Page 16: ...Page 12 6 GPS164 Features 6 4 4 IRIG Standard Format 12 Date 27th January 2016 GPS164 ...
Page 17: ...6 4 Time code outputs Page 13 6 4 5 AFNOR Standard Format GPS164 Date 27th January 2016 13 ...