7.3 BNC connector GPS Ant
Page 17
7.3 BNC connector GPS Ant
The antenna/converter unit is connected to the receiver circuit of the GPS164 through this connector.
7.4 Error Relay
On the front panel of the device you can nd a DFK connector labeled "Error". This is a potential free contact
which is directly controlled by the reference clock. Normally, when the reference clock is synchronized, the relay
and the relay contact NO is active. If the reception is diturbed or the device even turned o, the NC relay contact
is activated.
NO
NC
CO
Error
Technical Specication
Switching voltage/current AC
(resistive load):
max. 250 V, 1 A
Switching voltage/current DC
(resistive load):
max. 230 V, 0.1 A
max. 30 V, 1 A
Response time:
10 ms
Isolation coil/contact:
4 kV
Error Mode
CO NC NO
Error:
CO - NC connected
Normal Operation Mode
CO NC NO
Normal Operation:
CO - NO connected
WARNING: DANGER TO LIFE BY ELECTRICAL SHOCK!
NO LIVE WORKING !
Terminals of the error relay may be energized at dangerous voltage levels!
Do not carry out electrical works when terminals or signalling lines are
energized! All connectors must be equipped with suitable covers to prevent
from electrical shock or hazard!
GPS164
Date: 27th January 2016
17
Summary of Contents for GPS164-LQ/PPFO-3/REL-1/DAHS
Page 1: ...MANUAL GPS164 PPFO 3 REL 1 DAHS 27th January 2016 Meinberg Radio Clocks GmbH Co KG ...
Page 2: ......
Page 6: ...Page 2 1 General Details 2 Date 27th January 2016 GPS164 ...
Page 16: ...Page 12 6 GPS164 Features 6 4 4 IRIG Standard Format 12 Date 27th January 2016 GPS164 ...
Page 17: ...6 4 Time code outputs Page 13 6 4 5 AFNOR Standard Format GPS164 Date 27th January 2016 13 ...