Specifications
B3
ME-632
Inputs
16 digital inputs
Opto-isolation
up to 2500 VDC
Note:
The index „in“ refers to the clamps KL1…4; the index „out“ refers to the 78pin D-Sub female
connector.
Maximum Ratings
Conditions: T
A
=25°C
Recommended Operating Conditions
Conditions: U
b
=5V±10%, T
A
=25°C
Static Values
Conditions: U
b
=5V±10%, T
A
=25°C
Measurement Values
Test Conditions
MIN
MAX
Unit
Operating voltage U
b
non destructive
-0,5
+7
V
Input voltage U
in
non destructive
-5
70
V
I
out
non destructive,
1 channel
-60
+150
mA
U
ISO
f=60Hz, t=1min
2500
V
AC,rms
Measurement Values
Test Conditions MIN
Typ
MAX
Unit
U
in
0
60
V
I
out
t=1s, 1 channel
±60
±115
±200
mA
Measurement Values
Test Conditions MIN
Typ
MAX
Unit
U
in,H
2,30
60
V
U
in,L
0
2,20
V
U
out,H
I
out
=-24mA,
U
b
=4,5V
2,4
3,3
V
U
out,L
I
out
=24mA,
U
b
=4,5V
0,3
0,55
V
R
in
U
in
=24V
4,3
k
Ω
I
in
U
in
= 60V
6,5
10
mA