6.4.1 Requirements to the installation area
Ensure that the storage and installation area is permanently frost free.
If the system is installed in an area where the surrounding temperatures are below
0°C, the water freezing inside may damage the internal water components (pump,
solenoid valve, etc.).
6.5
Requirements to the electrical connection
DANGER
Risk of injury due to electric shock!
Work on the electrical machine components may be undertaken by specialist electri-
cians only.
The general electrical regulations must be observed when connecting the machine to
the power supply.
The relevant wiring diagram is available behind the front panel of the installation.
This wiring diagram must remain in the installation!
The type plate featuring electrical connected loads is available twice, 1 x visible from
the outside and 1 x behind the front cover panel.
The customer must guarantee the following points relating to the connection:
The correct voltage and type of current must be available
The power supply must be fused according to regulations with a mains sep-
arator in the permanently wired electrical installation.
If an unearthed neutral (N) is used with alternating current, the power dis-
connection device must have 4-poles (with alternating current 2-poles).
The installation must be connected to a potential equalisation system!
If the neutral line (N) is not earthed, you must use a 4-pin master switch.
Mains connecting leads must be oil-resistant, shielded cables no lighter than
an H 07 RN-F cable.
For connection to three-phase current a 5-pole terminal strip (L1, L2, L3, N,
PE) must be used.
Electricity supply without neutral conductor (N): when connecting to three-
phase current, use a 4-pole clamping strip (L1, L2, L3, PE).
Conductor colours: live conductor L1 = black/1, L2 = brown/2, L3 = gray/3,
neutral conductor N = blue/4, ground wire conductor PE = green-yellow.
The potential equalisation connection must be carried out in accordance with
the requirements of the local electricity supply company and all applicable
local regulations (in Germany VDE 0100 Part 540 must be observed).
The products are intended for permanent connection to the on-site power
supply and have been tested for the market accordingly. Any other form of
electrical connection is to be established by a licensed electrician.
Do not connect any additional consumers to the fuse protecting the installa-
tion.
Re-tighten all terminal fixing screws before the setting in operation.