background image

9680928 

10 / 16 

 

 

Safety instructions 

 

 

 

 
Due to its working principle,  the TopCut has a 

sharp blade

 at the front. In idle 

position, the blade is covered by the cutting unit and is not exposed until the 
washing chamber door is closed. 

In case of direct manual actuation of the 

TopCut there is a danger of injury by the blade!! 

 

 

 

If the TopCut is bent due to improper use the blade may remain exposed after 
actuation. In this case immediately disable the TopCut and secure against use! 
 

 

 

Insert the bags into the holder; do not throw them as this could cause the door 
to close unexpectedly! 
 

 

 

If the bag is not correctly cut open, place the bag in the holder again so that it 
is centred and cut the bag once more. If the TopCut again fails to cut, inform 
an authorised member of staff. 
 

 
 

After closing the chamber door, do not open it again, but immediately start the 
program. 
 

 

 

In case of service:

 Caution on replacing the the blade: 

Danger of injury!

 

 

 

Please observe proper use of the cleaning and disinfection device. Any other 
use or operations could cause damage and risks for which we can accept no 
responsibility. 

 

 

 

 

 

Wear personal protection (rubber gloves). To avoid contaminating the door 
handle and the control panel, you should remove your  protective gloves after 
filling the TopCut. Then disinfect your hands. Observe the operator's hygiene 
plan. 

 

 

 

Please read and observe the safety instructions and operating instructions for 
the cleaning and disinfection device. 

 

 

 

  

 

Before removing the TopCut, make sure that the blade has retracted correctly 
and that the holder is free of soiling. In dismounted state, carry the Der TopCut 
by the side facing the cutting unit. Do not use moving parts as a carrying aid. 
Handle the TopCut with care. Do not throw, swing or drop the device 
 
Do not use in machines with an automatic door! If it is used in machines with 
an automatic door, the high load produced can result in damage to the door 
mechanism and to the TopCut device itself.  

 

 

 
For your own safety and to avoid any danger do 

only

 use original MEIKO spare 

parts!

 

 

Summary of Contents for TopCut B

Page 1: ...pdate 2021 03 www meiko global com Operating instructions Universal vessel holder with urine and secretion bag cutter TopCut B Translation of the Original operating instructions Read operating instruc...

Page 2: ...NED USE 3 2 1 Suitable bag types 4 3 STRUCTURE 6 4 FUNCTIONAL DESCRIPTION 7 5 OPERATION INSERTING THE BAG 8 6 CLEANING 9 7 SAFETY INSTRUCTIONS 10 8 NOTES ON INSUFFICIENT FUNCTIONALITY OF THE TOPCUT 11...

Page 3: ...we reserve the right to make changes to the scope of supply concerning the design equipment and technical features at any time No claims may therefore be based on the details the images or the descri...

Page 4: ...ofix 1500 3500 Secretion bag 1500 2000 5000 Vacufix 1000 2000 3500 Curion CuriBag 1500 Dahlhausen Drainage bags 500 Gambrosol trio 40 2500 5000 Kendall mono FLO 2000 Oufora Standard 1500 Sarstedt MPL...

Page 5: ...5 16 9680928 BBraun Worek with outlet Curion CuriBag Kendall mono FLO BBraun Vacufix Serres 2000ml 3000ml...

Page 6: ...9680928 6 16 3 Structure Locking lever TopCut B Knives...

Page 7: ...inally at one corner 30 to 40 mm the bag then drains autonomously when the washing chamber is closed The bag is cut at the centre 30 to 40 mm the bag then drains autonomously when the washing chamber...

Page 8: ...basket in the direction of the arrow with your left hand Press down the lever with your right hand palm and simultaneously push the bracket forwards until the lever engages in front of the retaining...

Page 9: ...mme has finished it means the bag has been emptied and disinfected and can be removed 6 Cleaning When the programme has finished it means the bag has been emptied and disinfected externally The TopCut...

Page 10: ...anger of injury Please observe proper use of the cleaning and disinfection device Any other use or operations could cause damage and risks for which we can accept no responsibility Wear personal prote...

Page 11: ...unt or damaged and thus unable to penetrate the foil Call in authorised staff to replace the blade If the mechanical system is bent or does not run smoothly call in authorised staff to repair or repla...

Page 12: ...s when removing housing parts and when working inside the machine Before removing the TopCut make sure that the blade has retracted correctly and that the holder is free of soiling In dismounted state...

Page 13: ...TopCut into the bracket on the washing chamber door and secure in place with screws 2 Functional check Insert a filled urine bag you may prefer to fill the bag with water into the TopCut holder close...

Page 14: ...9680928 14 16 12 Spare parts list BAG CUTTER TOPCUT B 4 3 1 7 8 6 5 7 14 2 2 13 13 12 11 10 9 3 4 TopCut B...

Page 15: ...0308034 ZYLINDERSCHRAUBE PAN SCREW VIS CYLINDRIQUE 6 0340021 SCHEIBE DIN 125 A LIMPET DIN 125 A RONDELLE DIN 125 A 7 9667198 LAUFROLLE ROLLER POOULIE 8 9658626 MESSER KNIFE COUTEAU 9 9658624 WELLE 8X...

Page 16: ...Valid from 2009 09 Update 2021 03 MEIKO Maschinenbau GmbH Co KG Englerstra e 3 77652 Offenburg Germany www meiko global com info meiko global com Design and construction subject to change without prio...