Operating instructions Glass-, utensil- and dishwasher
M-iClean U
Operation/use
9763258
44 / 72
Design and construction subject to change without prior notice!
9.5.1
Messages
When a malfunction occurs, a grey or red message is shown on the display depend-
ing on the nature of the malfunction.
• Grey messages can be acknowledged using the relevant confirmation key.
• Red messages usually require the deployment of an authorised service techni-
cian.
No.
Display text
Note/possible cause
Measures/remedial action
1
Floor pan leakage
• There is a leak
• Minimum detection duration: 5
seconds to activation
• Not possible to continue work-
ing
• Call a service technician!
6
Programme cancelled
prematurely
• On/off key activated during
wash cycle
• Door was opened during the
rinse process
• Start wash cycle again
7
Door not closed
• Door is open
• Magnetic switch defective or ad-
justed incorrectly
• Cable breakage
• Plug connection to wiring
• Close the door
8
Door switch signals
not identical:
Switch left: "1"
Switch right: "0"
• Corresponding magnetic
switches/magnets, depending
on door position
• Cable breakage
• Plug connection to wiring
• Call a service technician!
• Possible to continue working at
limited capacity
9
Door switch signals
not identical:
Switch left: "0";
Switch right: "1"
• Corresponding magnetic
switches/magnets, depending
on door position
• Cable breakage
• Plug connection to wiring
• Call a service technician!
• Possible to continue working at
limited capacity
11
Carry out maintenance • Carry out maintenance
• Possible to continue working
• Call a service technician!
12
Access code wrong!
• Input code not available in inter-
nal table
• Enter correct entry code