Operating instructions wet waste treatment unit, Model AZP 80, AZ / AP 80
Datei:BA_AZP80_AZ_AP_9633432_EN_2005-10.docx
9633432
30/36
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
16.1 Basic safety measures during normal operation
Observe the maintenance periods prescribed in the operating instructions!
Wartungsanleitungen zu den Einzelkomponenten in dieser Betriebsanleitung beachten!
Before carrying out any maintenance or repair work, prohibit access to the operating area
to any unauthorized persons! Provide or display a sign drawing attention to the
maintenance or repair work!
Before carrying out any maintenance and repair work, switch off the electrical power at the
main electrical power switch and secure the switch with a padlock! The key for this lock
must be kept in the hands of the person carrying out the maintenance and repair work!
Failure to observe these precautions can result in severe physical injury or damage to
property
Before carrying out any maintenance and repair work, ensure that all the parts of the
machine that may be touched have cooled down to room temperature!
Carefully dispose of any lubricating, cooling or cleaning products that could harm the
environment!
16.1.1 Before starting operations following maintenance or repair
work
Before starting operations following maintenance or repair work, all initial tests must be
carried out as described in “Machine Settings for Initial Commissioning by the Service
Engineer”.
16.1.2 Observe the environmental protection regulations
Legal obligations relating to the avoidance of waste materials and to their recycling/removal
in accordance with applicable regulations must be observed!
In particular, during installation, repair and maintenance work, materials that could pollute
water such as:
•
Grease and oils
•
Hydraulic oils
•
Coolants
•
Cleaning fluids containing solvents
must not pollute the ground or run into the sewerage system! These materials must be
stored, shipped, collected and disposed of in suitable containers!
17
Maintenance recommendation
The gear lubricant oil of the screw should be exchanged after approx. 2 years. Shell gear
lubricant oil 90, resp. Shell-Omala 220, or a similar gear lubricant oil should be used. The
filling quantity is 1,7 l.
ONLY AP 80:
If necessary, the upper counter bearing of the screw must be greased
weekly with a commercial lubricator.
ATTENTION!