Quick Reference Guide

1

Diagnostic LED

2

i™Button Contacts

3

Service Tool Connector (i.e. CPM)

4

HII Interface Connector (i.e. Serial)

5

Route Inhibit Connector

6

Configuration Switches

7

Machine Interface Connector

8

Reject Lever

MEI
Eskdale Road,
Winnersh Triangle,
Wokingham, Berkshire, RG41 5AQ
http://www.meiglobal.com

Order - CF9500 Quick Reference Card Rev G2 - 2003

Coin Route Teach (Continued)

Example:- How to set a route C on a CF9524?
1) 

Power machine OFF

2) 

Set switch 7 to ON

3) 

Power machine ON

4) 

Press reject lever 3 times
(light will cycle the following sequence)

5) 

Insert required coins to be routed

6) 

Set switch 7 to OFF

Token 1 & Token 2 Teach

Switch 5 - Token 1 Teach - Switch 6 - Token 2 Teach
These switches allow you to teach tokens into 2 Token Channels.
Follow the instructions below to teach a token.

Coin Route Teach

Switches 7 and 8 - Route Teach
The acceptor has 4 routing priorities depending on the route inhibit
status, the first 3 routes can be taught using switches 7 and 8.
The order of priority is primary, secondary then tertiary.
E.g. If the primary route is full, the secondary route is then selected.

On a CF9524, route 'A' is the default route and on CF9528 route '8'.
All CF9500 acceptors leave the factory programmed with "all coins
to the default route".

To program a route, the reject lever will need to be pressed a
specific number of times. The Green light will flash a number of
times indicating the route selected. (See table below)

No.  of  Reject  Lever  Presses

0

1

2

3

4

5

6

7

No of Green Flash Codes

8

7

6

5

4

3

2

1

Route Selected (CF9524 - 4 way)

a

b

d

c

B

A

C

D

Route Selected (CF9528 - 8 way)

8

7

6

5

4

3

2

1

Route Inhibit Connector Pin No.

8

7

6

5

4

3

2

1

2

3

4

5

6

7

1

8

Step

Light

Operation and Action Required

Power Machine OFF

For Primary Route Set switch 7 to ON

For Secondary Route Set switch 8 to ON

For Tertiary Route Set switches 7 & 8
ON
Power Machine ON

Press Reject lever the number of times
for the required route.

Insert the coin for the required route

Inserted Coin Recognised – OK

Coin NOT Recognised (re-insert coin).

For Primary Route Set switch 7 OFF

For Secondary Route Set switch 8 OFF

For Tertiary Route Set switches 7 & 8
OFF
Route Taught – OK

Error - Re-try Route Teach again.

+ ?

Slow

Rapid

1

2

3

4

5

6

7

Step

Light

Operation and Action Required

Power Machine OFF

To Teach Token 1 Set switch 5 to ON

To Teach Token 2 Set switch 6 to ON

Power Machine ON

Insert Sample Tokens slowly. (min. x 20)

If inserted Token was recognised the
green light will flash once
When approx. 20 Tokens have been
inserted, CF9500 will flash the green light
rapidly
Set switch 5 to OFF ends Token 1 Teach

Set switch 6 to OFF ends Token 2 Teach

Tokens taught - OK

Error – Re-try teach again

Slow

Rapid

Rapid

1

2

3

4

5

6

7

CF9524 & CF9528 Separator Diagram

CF9524 Separator

(4 way)

D

A

B

C

CF9528 Separator

(8 way)

END VIEW

TOP VIEW

Coin Reject

1

2

3

4

6

5

7

8

Coin Tube Exits

Cash Box Exits

GB