GETTING STARTED 

At power up, the CF8000 will run a self test, where the CF8000 motor will sound. 
The LCD display briefly shows its software revision and as there are no coins in 
the tube cassette

, the display will show a “Low Tubes” message requesting that 

the coin tubes be filled to a predefined level (

refer to the floating coin tubes section

).  

Once the CF8000 has enough coins in the tubes, the LCD display will show the 
coin totals (in currency value) stored in the tubes. 
 
Note: MEI recommends that a small number of coins (e.g. 5 of each) be inserted 
in each tube prior to leaving the machine. 
 
Floating the Coin Tubes 
There are two ways to float the CF8000 tubes with coins. 
1)  Manually fill each tube by inserting coins into the tubes. 
2)  Use the Service Mode and insert coins through the discriminator. 
 
Filling Tubes Manually 
1.  Remove the tube cassette from the CF8000. 
2.  Insert required number of coins into relevant storage tubes. 
3.  Re-fit tube cassette back on to the CF8000. 
The CF8000 will now begin an automatic tube calibration measurement where a 
clicking sound will be heard, this is normal.  Once calibration is complete the 
display will show a total currency value of the coins inserted.  If a tube is left 
empty the display will show a tube low message for the particular tube. 
 
Fill Tube using Service Mode 
1.  Press the Yellow ‘Mode’ button once. 
2.  Press ‘A’ button and start inserting coins through the discriminator. 
3.  The display will show the number of coins that are required for each tube.  

(the displayed count will decrement as coins are inserted) 

4.  Press ‘A’ button to exit float mode. 
 
CF8000 Menu Structure 
Setup Mode  
There are two ways to access the Setup Mode menus. 
1.  Press and hold the ‘Mode’ button for 2 seconds. 
2.  Press the ‘Mode’ button once and select the ‘Setup’ option by pressing 

button ‘E’.  (This method requires a pass code.  When asked for this, press 
buttons ‘A’‘B’‘C’). 

Summary of Contents for CASHFLOW 8000 Series

Page 1: ...Part Number 79xxxxxxx Rev G1 START UP GUIDE CASHFLOW 8000 Series Change Manager GB...

Page 2: ...nto the vending machine by hanging it onto three studs located on the vending machine To do this you will need to open the discriminator assembly and line up the mounting keyholes of the CF8000 with t...

Page 3: ...chine door tuck any unused cables away tidily ensuring that none are trapped between the reject lever mechanism and the vending machine door You can now switch ON the power to the vending machine 4mm...

Page 4: ...Mini USB link to PC The blue keys marked A to E have two functions When the CF8000 is in idle mode pressing a blue button on its own will dispense a coin from that tube When you press and hold the blu...

Page 5: ...e the tube cassette from the CF8000 2 Insert required number of coins into relevant storage tubes 3 Re fit tube cassette back on to the CF8000 The CF8000 will now begin an automatic tube calibration m...

Page 6: ...Insert a coin and then press the reject lever Enable a coin Insert a coin and then press Mode button View coin details press to scroll up press to scroll down View channel set press to exit view Teach...

Page 7: ...ode button once 2 Press button E to select Setup 3 Enter pass code Press A B C 4 Press button D to scroll up the menu an until the display shows Language 5 Press Select then Edit 6 Use button D or E t...

Page 8: ...be cassette error Dispenser module error Predefined Cassettes The CF8000 has stored in memory a selection of predefined tube cassettes that provide different payout options These additional payout opt...

Page 9: ...er only Sfera 2006 S W files needed 4K Board Astro 2006 Jack looms only Snack Brio Rondo Kikko Canto Necta Sambo All Eprom variants no Audit Brela Mistral Azkoyen Palma BVM Bianchi LEI New Machines De...

Page 10: ...hat indicated Operating Temperature Ambient Operating Temperature 15 C to 70 C Dangerous Environments The CashFlow 8000 Series must not be operated in the presence of flammable gasses fumes or water T...

Reviews: