CashFlow
®
540 changegiver Pocket Guide
38
,
MEI., 1997
Installing, Starting and Testing
a CashFlow
Unit
Before installation...
1. Check that the unit’s specifications are correct
for the host machine.
2. Ensure that the unit’s modules are assembled
securely.
3. Check that the connector on the unit’s loom
matches the one on the host machine.
4. Confirm that the voltage of the power supply to
the changegiver is the same as that shown in the
keypad window of the changegiver.
Fit the changegiver onto the locating
screws in the machine
1. Ensure that the unit is level on its three keyhole
mounting slots.
2. Check that the right-hand mounting screw is at
the top of the keyhole slot, and that the unit is level.
3. Press down the top cover flap and tighten the
right-hand mounting screw to secure the unit in
place in the machine.
Tighten the screw in the
right-hand keyhole slot
to secure the unit in the
host machine
Note the model
number and serial
number before
you contact your
MEI distributor
Mounting points